Alignment of the machine torch
Mount the machine torch perpendicular to the material to be cut, use a square to align the torch
at 0 ° and 90 °, if torch alignment is not possible, check the cutting table for level to obtain a true
vertical cut�
Operating the machine torch
WARNING
Plasma arc is generated immediately
when the CNC start signal is ON
The plasma arc will cut quickly through gloves and skin�
Make sure the power supply is switched off before changing consumables�
•
Keep away from the torch tip�
•
Do not hold the piece that is to be cut and keep your hands away from the cutting path�
•
Never point the torch toward yourself or toward others�
•
Never use with the pendant control switch�
Important:
In case of operation of the power supply equipped with 23 m long torch you have to increase
dynamic gas pressure to value 6�5 bar�