EX-TRAFIRE
®
40SD
Operator manual, Revision T-15
9
Safety Sticker
WARNING!
Plasma arc is generated immediately
when the torch trigger is depressed.
Plasma arc is generated immediately when the torch trigger is
depressed. The plasma arc will cut quickly through gloves and skin.
Make sure the power is switched off before changing consumables.
+
=
+
1
2
3
4
6
2.1
3.1
3.2
3.3
4.1
4.2
4.3
5.1
5.2
5.3
6.1
6.2
6.3
5
7
Torch consumable installation
Safety instructions
EX-0-904-003
N-21191
Machine Shield
Deflector
Hand Shield
1. Screw the electrode. Use the electrode wrench
(EX-2-427-010). Do NOT overtighten electrode.
2. Insert the swirl ring. Must seated properly. CAUTION:
Direction of the swirl ring is important! The tip of the laser
marked arrow indicates the installation direction!
3. Perform free movement test of the electrode inside the swirl
ring (by pushing the electrode).
4. Insert the nozzle on the swirl ring.
5. Screw in the nozzle retaining cap and tighten by hand.
Do NOT overtighten.
6. Screw on the hand (contact) shield, machine shield or
deflector (and tighten by hand). Do NOT overtighten.
Summary of Contents for EX-TRAFIRE 40SD
Page 10: ...EX TRAFIRE 40SD Operator Manual Revision T 15 10 Blank page...
Page 65: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 65 Notes...
Page 66: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 66 Notes...
Page 67: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 67 Notes...
Page 68: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 68 Notes...
Page 70: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 70 Revision history...