Introduction
...............................................................
1. Safety Certifications
..............................................2
2. Specifications
.......................................................2
3. Operation
............................................................2
3. Transporting ...................................................2
3.2 Electrical Requirements ..................................2
3.3 Condensate Removal ......................................3
3.4 Ducting ..........................................................3
3.5 Defrost Cycle .................................................3
3.6 Power Button .................................................3
3.7 Purge Button ..................................................3
3.8 Hour Meter ....................................................3
3.9 Hours Button .................................................3
3.0 Defrost Light ................................................3
4. Maintenance
........................................................3
4. Air Filter .........................................................3
4.2 Storage .........................................................4
5. Service
................................................................4
5. Technical Description ......................................4
5.2 Troubleshooting ..............................................4
5.3 Air Mover .......................................................5
5.4 Thermistor .....................................................5
5.5 Condensate Pump ..........................................6
5.6 Float Safety Switch .........................................6
6. Options & Accessories
..........................................6
7. Wiring Diagram
....................................................6
8. Service Parts
.......................................................7
9. Warranty
..............................................................9
1 Safety Certifications
The Phoenix R75 conforms to standards ANSI/UL 474
and CSA C22.2 No.92.
2 Specifications
Part No.
4026300
Power
6. amps, 0-20 VAC, Grounded
Water
92 pints/day @ AHAM (80°F, 60%)
Removal
2 gal/day maximum @ saturation
Blower
230 CFM without external ducting
20 CFM @ .5 IWG external static
Refrigerant
lb, 0 oz. R-22
Charge
Operating
33°F to 05°F
Range
Filters:
2” x 2” x ” Pleated Media MERV-7
Duct
Intake – 2” Flex-Duct
Options
Supply – 0” Lay-Flat
Warranty
Five years;
st year 00% of Parts and Labor
2nd-5th year 00% of Parts of sealed
refrigeration system.
Dimensions
Unit
Shipping
Width
20”
24”
Height
33.5”
45.25”
Depth
20”
25.5”
Weight
05 lbs
0 lbs
3 Operation
Place dehumidifier inside structure,
place condensate hose into a drain, or
a very large container, and turn on. To
decrease drying times, make sure all
windows and doors are closed to the
outside and seal off the wet area from
any unaffected areas.
3.1 Transporting
The Phoenix R75 features a high-
impact roto-molded housing which
protects the unit airways, and while
loading into vehicles. The unit was designed to make it
easy to stack two high. The wheels of the top unit ‘nest’
in the indentations of the bottom unit to provide stability.
It is recommended the units are properly secured for
transport. The Phoenix R75 must always be upright when
transported by vehicle. It may be tipped onto its handle
and back for loading and moving by hand.
Read the operation and maintenance instructions
carefully before using this unit. Proper adherence to
these instructions is essential to obtain maximum
benefit from your Phoenix R75 dehumidifier.
• It is designed to be used
INDOORS ONLY.
• If used in a wet area, plug it into a
GROUND FAULT
INTERRUPTER
.
•
DO NOT
use the Phoenix R75 as a bench or table.
• It must always be used in the upright position.
Figure 1: Stacked
Phoenix R175