Page 1: ...gy Co Ltd Wine Cellar Cooling Units Self contained User Manual Thank you for purchasing this Thenow product Please read this manual carefully before attempting to install operate or service Please ret...

Page 2: ...ore than 24 hours before it can be turned on The power cord must be plugged into a 3 prong grounding type wall receptacle Do not attempt to carry out any measurement device replacement or other mainte...

Page 3: ...1 Product Introduction 4 2 Dimensions Technical Data 6 3 Installation Debugging 9 4 Introduction of Controller 19 5 Maintenance 23 6 Troubleshooting 24 7 Warranty 26 Table of Contents...

Page 4: ...noise Optimal air distribution ensures the most uniform temperature in the wine cabinet space Commercial grade corrosion resistant components and spray painting frame for long term durability Build i...

Page 5: ...ondensing heat generated from refrigeration can be exhausted to outside to achieve the purpose of adjusting the indoor temperature 2 Dehumidification Principle When the wet air flows through the evapo...

Page 6: ...Dimensions HSN JC5 Dimensions Technical Data...

Page 7: ...Dimensions HSN J15 Z...

Page 8: ...97 310 1176 440 350 Drainage mm Self absorption 20 Cooling capacity on above sheet test conditions Cellar inside dry bulb t 12 60 Outside dry bulb t 35 wet bulb t 28 Note There are several factors suc...

Page 9: ...dered C The appearance of the whole machine is intact D Check the below packing details HSN J15 Z Packing Details Item No Item Q ty Size Photo 1 Unit 1 set See the nameplate 2 User Manual 1 pc A5 3 Co...

Page 10: ...tails Item No Item Q ty Size Photo 1 Unit 1 set Refer to the namplate 2 User Manual 1pc A5 3 Control Panel 1 pc 90 90mm 4 Controller Cable 3m Warning Our company is not responsible for any accident ca...

Page 11: ...an extension cord However if you still elect to use an extension cord it is absolutely necessary that it will be a related national standard LISTED 3 wire grounding type appliance extension cord havin...

Page 12: ...JC5 Installation II Wine Cabinet with Large Space Internal Fan with High Speed...

Page 13: ...JC5 Installation III Wine Room...

Page 14: ...2 HSN J15 Z Wine Cabinet Wine Room Installation J15 Z Installation I Wine Cabinet with Small Space Internal Fan with Low Speed...

Page 15: ...J15 Z Installation II Wine Cabinet with Large Space Internal Fan with High Speed...

Page 16: ...J15 Z Installation III Wine Room Installation...

Page 17: ...ced in the bottom and side of the unit 7 Working environment Temperature 5 35 Humidity RH 80 8 Recommend air duct A Heat insulating phenolic board thickness 15 20mm B Stainless steel duct 20mm insulat...

Page 18: ...ng automatically according to the setting value 4 Keep the machine running at least 30 minutes After the machine runs for 30 minutes 1 Check the alarm record If all functions work well no alarm record...

Page 19: ...matic operation of the appropriate air flow speed comfortable energy saving accurate and reliable Functional features 1 With 4 inch capacitive full touch display clear picture and easy to operate 2 Re...

Page 20: ...the plastic frame and screw from the packaging box and then install and fix the plastic frame to the 86 mounting box inside the wall after the wire is threaded out of the plastic frame 2 Correct wirin...

Page 21: ...ature 4 Setting humidity 5 Running mode display Constant Temperature Constant Humidity Auto Ventilation 6 Coil temperature 7 Running Mode Setting 8 Fan running mode Manual Auto 9 Fan air flow setting...

Page 22: ...nd Humidity click to enter and set humidity Set time 1 Touch icon Set 2 Find Time click to enter and set time Mode Touch icon Mode to choose the running mode default value is Auto Fan Running Mode Tou...

Page 23: ...ture and high humidity environment if excess condensate may be generated in the wine cabinet this part of the condensate needs to be manually removed JC5 in this series of products are self absorbent...

Page 24: ...5 C or lower 5 C 6 Setting higher than ambient temperature 7 Defrosting mode on 1 Check power at receptacle fuses 2 Plug in power cord plug 3 Contact an authorized electrician 4 Check all wirings and...

Page 25: ...6 Add refrigerant Unit running too long or continually 1 The machine model choice is improper or improper room sealing 2 Ambient temperature to high 1 Check machine mode or check room tightness 2 Che...

Page 26: ...ine quality reasons for damage is not covered by the warranty Commitment in after sales service During the warranty period our company is responsible for the maintenance of the equipment if the equipm...