B-33
Themis Computer
BIOS Setup Utility
BIOS POST Messages
B.8
BIOS POST Messages
During the Power-On Self-Test (POST), the BIOS will check for problems. If a
problem is found, the BIOS will activate an alarm or display a message. The follow-
ing is a list of such BIOS messages.
Failure Fixed Disk
Fixed disk is not working or not configured properly. Check to see if fixed disk is
attached properly. Run Setup. Find out if the fixed-disk type is correctly identified.
Stuck key
Stuck key on keyboard.
Keyboard error
Keyboard not working.
Keyboard Controller Failed
Keyboard controller failed test. May require replacing keyboard controller.
Keyboard locked - Unlock key switch
Unlock the system to proceed.
Monitor type does not match CMOS - Run SETUP
Monitor type not correctly identified in Setup
Shadow Ram Failed at offset: nnnn
Shadow RAM failed at offset
nnnn
of the 64k block at which the error was detected.
System RAM Failed at offset: nnnn
System RAM failed at offset
nnnn
of in the 64k block at which the error was
detected.
Extended RAM Failed at offset: nnnn
Extended memory is not working or not configured properly at offset
nnnn
.
Summary of Contents for CoolShell CS-3U
Page 16: ...xiv Themis Computer CoolShell CS 3U Installation Manual...
Page 22: ...xx Themis Computer CoolShell CS 3U Installation Manual...
Page 40: ...2 8 Themis Computer CoolShell CS 3U Installation Manual...
Page 52: ...A 12 Themis Computer CoolShell CS 3U Installation Manual...
Page 90: ...CoolShell CS 3U Installation Manual B 38 Themis Computer...
Page 110: ...C 20 Themis Computer CoolShell CS 3U Installation Manual...