2-3
Themis Computer
Installation and Operation
Installation Procedures
4.
Firmly push the 3RU subrack into the rear alignment guide-pins until the sub-
rack is secure and the front of the subrack is flush with the front of the 19”
rack.
5.
Secure the 3RU subrack to the front of the 19” rack with four to six 10-32”
round-head screws, two or three on each side (see
2.1.2
CoolShell CS-3U Installation
Follow these steps to properly install the CoolShell CS-3U after the 3RU subrack
has been firmly attached to the 19” rack:
1.
Reinstall each of the CoolShell CS-3U components (CPU Blade, I/O Blade,
Media Module, and power supplies) previously removed from the 3RU sub-
rack.
2.
Connect the video display cable to one of the two DVI connectors (third or
fourth from the left or right) on the middle PCI-Express card of the I/O Blade
(see
on page 2-4). Connect the other end of the cable to a video dis-
play. If you are connecting multiple video displays, see Section 2.1.3, “Multi-
ple Video Displays”.
Note:
The fully installed alignment guide-pins are strong enough to hold the 3RU
subrack until it is secured to the front of the 19” rack—see Step 5.
Figure 2-4.
CoolShell CS-3U
3RU Subrack Secured to the 19” Rack
19” RETMA Rack
CS-3U 3RU Subrack
Screw
Placement
1.75”
1.75”
1.75”
1.75”
Screw
Placement
Note:
Rear 19” rack uprights are not shown.
Summary of Contents for CoolShell CS-3U
Page 16: ...xiv Themis Computer CoolShell CS 3U Installation Manual...
Page 22: ...xx Themis Computer CoolShell CS 3U Installation Manual...
Page 40: ...2 8 Themis Computer CoolShell CS 3U Installation Manual...
Page 52: ...A 12 Themis Computer CoolShell CS 3U Installation Manual...
Page 90: ...CoolShell CS 3U Installation Manual B 38 Themis Computer...
Page 110: ...C 20 Themis Computer CoolShell CS 3U Installation Manual...