1-7
Themis Computer
Overview and Specifications
Specifications
1.3.2.1 Shock
The CoolShell CS-3U is designed to survive an elevated shock environment. All
structural components are welded together, enabling the system to survive a maxi-
mum 3-axis shock load of 25G at 20-msec duration.
1.3.2.2 Electrostatic Discharge
The CoolShell CS-3U is designed to tolerate electrostatic pulses up to 15 kilovolts
(KV) with no impact on system operation.
1.3.2.3 Noise Level
Typical noise levels emitted by the CoolShell CS-3U are outlined in
. The
chassis is installed with four 38-mm fans contained side-by-side in a single fan
assembly.
1.3.3
Regulatory Compliance
The CoolShell CS-3U is designed to comply with the MIL-STD-882D safety stan-
dard. In addition, it meets the regulatory requirements listed in
.
1.3.4
RoHS Compliance
The CoolShell CS-3U is designed to be RoHS-compliant consistent with standards
for commercial computing equipment.
Table 1-3.
Typical Noise Levels of the CoolShell CS-3U
Measured at:
1 Meter
2 Meters
Front
66.24 dB
57.57 dB
Rear
61.53 dB
57.93 dB
Table 1-4.
Regulatory Compliance Specifications
Parameter
Specification
Radiated and Conducted Emissions
FCC Class A
PCB FAB Material
94VO Rating
Summary of Contents for CoolShell CS-3U
Page 16: ...xiv Themis Computer CoolShell CS 3U Installation Manual...
Page 22: ...xx Themis Computer CoolShell CS 3U Installation Manual...
Page 40: ...2 8 Themis Computer CoolShell CS 3U Installation Manual...
Page 52: ...A 12 Themis Computer CoolShell CS 3U Installation Manual...
Page 90: ...CoolShell CS 3U Installation Manual B 38 Themis Computer...
Page 110: ...C 20 Themis Computer CoolShell CS 3U Installation Manual...