Gas Line Installation
The gas line must be installed in accordance with all
local codes. See Figure 8 for location of gas hook-up
on back of heater. The gas line must be purged and
this hook-up checked for gas leaks before proceeding
to light pilot. A gas line shut-off valve is required no
more than 3’ upstream from the heater. Note: The gas
hook-up on the back of the heater is 3/8” N.P.T.
When pressure testing the gas supply at test pressures
in excess of 1/2 psig (3.5kPa) you must isolate the
heater from the supply line by disconnecting or
utilizing the gas shut off valve.
OPERATION
Location of Controls
See Figure 8 for location of controls. Control
functions are outlined below.
Gas Control Knob
This knob is used for starting the pilot and has three
(3) positions: On, Off, and Pilot. The pointer directly
above the knob indicates the position the knob is in.
Hi/Lo Flame Adjust
This knob controls the burn, either high or low. It is
operated manually by turning the knob. Once in
position, the wall thermostat will turn on the burner
to the position which this knob is set.
Pilot Igniter
This button is used to ignite the pilot. It is pushed in
while the gas control knob is in the Pilot position.
When pressed, it creates a spark at the pilot, igniting
it.
Burner On/Off Switch
This switch turns the burner on after the pilot is lit.
When the wall thermostat is hooked up, this switch
will remain in the “On” position after the pilot is lit.
The wall thermostat will then turn the heater on
automatically when indicated.
Fan Control Knob
This knob controls the speed of the room fan after the
fan comes on.
NOTE: The fan comes on automatically after the
heater gets warm, usually about 10 to 15 minutes.
Wall Thermostat Control (Millivolt Thermostat
Mandatory)
Hook thermostat wire (2) to the terminals as
indicated in Figure 8, if you choose the wall
thermostat option. Keep in mind the heater will run
until the thermostat signals it is too hot in the room.
It will then turn the heater to pilot only. Location of
the wall thermostat is crucial. If it is too close to the
heater, the unit will shut down frequently. If it is too
far away, the heater will run longer than may be
necessary. Place the wall thermostat approximately
twelve (12) feet from the heater.
NOTE: Remove small wire shunt before hooking up
wires.
1.
Push the gas control knob in slightly and turn
clockwise to the “Off” position. NOTE: The
knob will not turn from “On” to “Off” unless the
knob is depressed. Do not force!
2.
Wait five (5) minutes to clear out any gas, then
again smell for gas, including near the floor. If
you smell gas, STOP and follow the instructions
outlined at the beginning of this manual.
Summary of Contents for PARLOUR 3000-MV
Page 8: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 8 LABORATORY LISTING LABEL...
Page 10: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 10 FIGURE 1 DIAGRAM OF DIMENSIONS...
Page 15: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 15 FIGURE 4 VENT TERMINATION LOCATIONS...
Page 18: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 18 FIGURE 5 DIAGRAM OF VENTING REQUIREMENTS...
Page 23: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 23 FIGURE 8 DIAGRAM OF CONTROL COMPONENTS...
Page 33: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 33 FIGURE 12 GAS VALVE AND PILOT ASSEMBLY...
Page 35: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 35 APPENDIX B PARLOUR STOVE WITH BURNER...