FIGURE 6 – VENT TERMINATION
Wind flow over roof structures can often cause localized pressure disturbances. Vent termination must take into
account these disturbances and minimize them by using the following table to maintain the correct legal height
of the vent.
NOTE: If your installation involves a roof with a slope greater than 6/12 or if a wall or other vertical obstruction
is within 8’ of the vent termination, the vent termination will have to be taller in accordance with the following
table.
Roof Pitch
H (Min.) Ft.
Flat to 6/12 ....................................1.0
Over 6/12 to 7/12 ........................1.25
Over 7/12 to 8/12 ..........................1.5
Over 8/12 to 9/12 ..........................2.0
Over 9/12 to 10/12 ........................2.5
Over 10/12 to 11/12 ....................3.25
Over 11/12 to 12/12 ......................4.0
Over 12/12 to 14/12 ......................5.0
Over 14/12 to 16/12 ......................6.0
Over 16/12 to 18/12 ......................7.0
Over 18/12 to 20/12 ......................7.5
Over 20/12 to 21/12 ......................8.0
Summary of Contents for PARLOUR 3000-MV
Page 8: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 8 LABORATORY LISTING LABEL...
Page 10: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 10 FIGURE 1 DIAGRAM OF DIMENSIONS...
Page 15: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 15 FIGURE 4 VENT TERMINATION LOCATIONS...
Page 18: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 18 FIGURE 5 DIAGRAM OF VENTING REQUIREMENTS...
Page 23: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 23 FIGURE 8 DIAGRAM OF CONTROL COMPONENTS...
Page 33: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 33 FIGURE 12 GAS VALVE AND PILOT ASSEMBLY...
Page 35: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 35 APPENDIX B PARLOUR STOVE WITH BURNER...