1
LUXA 103-100 AP WH
1030022
LUXA 103-101 AP WH
1030023
307344
Motion detector
EN
1. Basic safety information
Danger of death through electric shock or fire!
¾
¾
Installation should only be carried out by a
qualified electrician!
WARNING
•
The device conforms with EN 60669-2-1 if installed
correctly
2. Proper use
•
Motion detector for automatic lighting control dependent
on presence and brightness (LUXA 103-100 AP); LUXA
103-101 AP: suitable for automatic lighting and HVAC
control (HVAC switches on regardless of brightness)
•
Suitable for ceiling installation indoors with back boxes
•
Suitable for toilets, small rooms, workplaces, offices, etc.
Disposal
¾
Dispose of the device in an environmentally sound manner
(electronic waste)
3. Device description
3 potentiometers for setting
time delay (TIME), bright-
ness value (LUX) and detec-
tion area (METRES) (under
the cover);
additional setting of HVAC
time (TIME 2) in the case of
LUXA 103-101 AP
red LED
4. Installation and connection
!
Secure device with an upstream type C circuit breaker (EN
60898-1) with a maximum of 10 A (channel 1)
!
Secure device with an upstream type C circuit breaker (EN
60898-1) with a maximum of 6 A (HVAC channel 2)
Installing the motion detector
L
Installation height: 2 – 3 m
L
Motion detector requires clear line of sight to people
¾
Disconnect power source
0FF
230V
¾
Carefully lift the outer cover with a screwdriver and
unscrew the upper housing part
2
¾
Observe the break-outs for flush-mounting socket
B
5 6
60
70
80
84
A
8 0
84
70
6 0
5 6
¾
Strip cable to 6 – 8 mm
6
30 - 35mm
- 8 mm
5
6
6
0
70
80
8
4
N
L
L
D1 D2
5
6
6
0
70
8
0
8
4
¾
Make marks for the holes and drill the holes
60
56
60
¾
Fix the base to the ceiling, connect the individual wires to
the appropriate terminal and tighten the screws
¾
Screw on the housing
60
56
60
¾
Make settings at the potentiometers
¾
Put on the cover and close catch mechanism
¾
Connect motion detector to power supply