The Splash Lab TSL.C.050 Installation & Maintenance Download Page 1

TSL 050

.C.

channel sensor faucet

in

st

all

ation + m

ain

ten

an

ce

Summary of Contents for TSL.C.050

Page 1: ...TSL 050 C channel sensor faucet installation maintenance...

Page 2: ...Data 6 Before You Install 8 How to Install 10 The Complete System 11 Resetting the Sensor 13 Maintenance 13 Cleaning 14 Spare Parts 14 15 Product ldenti cation Troubleshooting 16 Warranty Back Cover...

Page 3: ...t the manufacturer This equipment should be installed in a way that ensures all electrical parts are kept dry A means of electrical isolation must be incorporated in the xed wiring in accordance with...

Page 4: ...ntents Channel sensor faucet head B Mains power supply C Solenoid valve D Pad E Gasket F Washer G Fixing nut H Flow restrictor I Flex hose 300mm A A B C D E F G H I 4 TSL C 050 CHANNEL SENSOR FAUCET M...

Page 5: ...r range Minimum Sensor range Maximum 5 3 20 5 9 20 technical data Finishes TSL C 050 C Bright Polished TSL C 050 CS Brushed Stainless TSL C 050 CP Brushed Copper TSL C 050 BK Brushed Black TSL C 050 B...

Page 6: ...before you install 6 TSL C 050 CHANNEL SENSOR FAUCET MANUAL FIXING SIDE FRONT Sensor Range 3 15 16 Sensor wire Flexi hose 2 9 5 16 1 2 PF 35 7 16 21 5 8 21 5 8...

Page 7: ...mperature control Premixed Channel water must therefore be supplied separately Sinks Use of a The Splash Lab sink is recommended when used in conjunction with any of the The Splash Lab Channel xtures...

Page 8: ...h Lab that there will be no re ection or splash issue Basins The Splash Lab o ers an optional backplate for the xtures that means the xtures can be mounted from the front and have simpler access Backp...

Page 9: ...how to install 1 Drill hole 1 3 16 diameter in wall 8 10 above the bottom of the basin 2 Fit faucet body into the 1 3 16 hole in wall TSL C 050 CHANNEL SENSOR FAUCET MANUAL 9 1 3 16...

Page 10: ...3 Thread the sensor wire and exi hose through the gasket washer and xing nut then tighten the nut against the installation wall 10 TSL C 050 CHANNEL SENSOR FAUCET MANUAL...

Page 11: ...Water Aerator A Channel sensor faucet head B Mains power supply C Solenoid and cable H Flow restrictor the complete system A C B H TSL C 050 CHANNEL SENSOR FAUCET MANUAL 11...

Page 12: ...out 2 below the sensor on the tap head and keep it there for 3 seconds First disconnect the Channel Tap head from the Power unit Wait a minimum of 4 seconds and reconnect the power solenoid cable Brow...

Page 13: ...etting up the desired sensor range Remove re ective clothing during installation At the end of the 3 seconds move your hand away from the senor and down towards the wash basin to set the desired senso...

Page 14: ...ng service life of the sensor faucet Use a soft cloth or sponge with a mild solution of soapy water as part of the regular washroom janitorial routine Do not use abrasive or cream cleaners as these wi...

Page 15: ...me non functioning during normal use within their assumed usable life they may be replaced Should a replacement mains power supply be required it is imperative that an identical type is used Contact T...

Page 16: ...pen Water supply is blocked to valve Check and clean lter on solenoid valve Check water supply for any blockages or restrictions Water pressure is too low Check pressure of water supply Water does not...

Page 17: ...ranty Non operation of the product due to environmental conditions beyond our control installation error incorrect maintenance water quality fair wear and tear incorrect or inappropriate installation...

Page 18: ......

Page 19: ......

Page 20: ...formation 310 410 5008 Technical support info thesplashlabusa com For further contact information visit www thesplashlabusa com Warehouse O ces 20809 Higgins Court Torrance CA 90501 Showroom 8745 Wash...

Reviews: