9.3: NBS90
SP
A
IR
S
UPPLY
R
EQUIREMENTS
NBS90 SP PNEUMATIC REQUIREMENTS
•
Maximum conveyor length each way from regulator is 80'. Locate regulator in center of
conveyor, if possible, for maximum efficiency.
•
Overhead feeder line pressure to be 100 PSI minimum
•
Low pressure switch to be set at 90 PSI
•
In high humidity or low temperature, use air dryer
•
Use 5 micron filter
•
Lockout/shutoff valve to be provided by air system installer
•
Regulators pressure set to unit requirements:
NBS90 SP
•
Air take-up 50-55 PSI
•
90º transfer 45-50 PSI
NBS90 SP Formulas
NBS 90SP transfers are actuated by a single air cylinder with a 2" bore and 1/2" stroke.
The air consumption per transfer is calculated by:
•
.0092CF (cubic feet) X CPM (cycles per min.) = SCFM (Standard Cubic Feet / Minute)
Adding together the air requirements of all transfers connected to one regulator will give total air flow
requirements for that NBS air system.