NBS®90 PolySort & SP IOM
P/N: 1193974
Revision Date: 4/25/2019
Page
55
of
83
9.2: NBS90
P
OLY
S
ORT
A
IR
S
UPPLY
R
EQUIREMENTS
Pneumatic pressure requirements:
•
Maximum conveyor length each way from regulator is 80'.
•
Locate regulator in center of conveyor, if possible, for maximum efficiency.
•
Overhead feeder line pressure to be 100 PSI minimum.
•
Low pressure switch should be set at 10 PSI below the operating air pressure for the specific
device noted below.
•
In high humidity or low temperature, use air dryer.
•
Use 5 micron filter.
•
Lockout/shutoff valve to be provided by air system installer.
Regulators pressure set to unit requirements:
•
Air take-up
50-55 PSI
•
90º PolySort transfer
50-55 PSI
NBS90 PolySort Diverters are actuated by four air bags.
The air consumption per divert is calculated by:
•
.072CF (cubic feet) X CPM (cycles per min.) = SCFM (Standard Cubic Feet / Minute)