IOM CRUZcontrol®
P/N: 90480009
Revision Date: 03/18/2019
Page
14
of
58
Power Supply Requirements
CRUZcontrol operates from a nominal supply voltage of 24 volts DC. The wiring methods and
componentry used are such that a Class 2 power supply should be used. This limits the output power to
a total of 100 VA. The current required for each CRUZcontrol Logic Assembly is 67mA, which allows for
up to 53 zones per power supply. There is also a limit on the maximum number of Logic Assemblies that
can be in one continuous string, based on the cable length from the power supply to the first Logic
Assembly:
More than one string of Logic Assemblies can be connected to a power supply, up to the maximum of 53
zones.
Power Supplies
The following power supplies are available from TGW Systems. Technical specifications for each are
included with this manual.
TGW Systems Part No.
Description
1101825
100-250 VAC input Power Supply Kit including T cable and
Mounting Bracket. (reference Cutler-Hammer # PS256A-
01B1)
94510092
342-528 VAC 3 phase input Power Supply Kit including a T
cable and a Mounting Bracket. (reference C-H # PS256A-
44B1)
Cable length – power supply to first Logic Module
Assembly
3 ft
9 ft
13 ft
Maximum # of Logic Module Assemblies per string
33
32
31
Maximum # based on zones greater than 36 inches
24
23