IOM CRUZcontrol® Generation2 for NBC
P/N: 1118211
Revision Date: 05/31/2019
Page
14
of
66
3.5: D
EFINITION
O
F
T
ERMS
Logic Assembly
The logic assembly is to setup the type of automatic accumulation and discharge of product on the
conveyor.
Function Module
The function module provides electrical isolation for external signals used to control a CRUZcontrol
system.
Downstream or Upstream
In this manual, it is always in reference to conveyor flow.
OFF
Off indicates a logical low signal and/or no power. For example if a logic line is OFF, there is no power
on the logic line.
ON
On indicates a logical high signal and/or powered. For example if a slug line is ON, then there is power
on the slug line.
Zone status
The zone is considered full if the local zone’s sensor detects a package. The zone is empty if it does
not detect a package
JP#, #-#
JP stands for “jumper terminal” and the number indicates which jumper terminal is being referenced.
The “#-#” refers to the pins that are connected by the actual jumper. NC means the jumper is not
connected to any terminal.
Ex. jumper terminal #1 pins 1 & 2 (JP1, 1-2)
TB#, #-#
TB stands for “terminal block” and the number indicates which terminal block is being referenced. The
“#-#” refers to the pins that are being used on that terminal block.
Ex. terminal block #1 pins 1 & 2 (TB1, 1-2)