©Copyright Task Force Tips LLC 2021
24
LIY-350 January 13, 2021 Rev00
TASK FORCE TIPS LLC
MADE IN USA · tft.com
3701 Innovation Way, Valparaiso, IN 46383-9327 USA
800-348-2686 · 219-462-6161 · Fax 219-464-7155
10.0 OPERATION AND INSPECTION CHECKLIST
BEFORE EACH USE,
appliances must be inspected to this checklist:
3. All valves (if so equipped) open and close fully and smoothly
4. Waterway is clear of obstructions
5. There is no damage to any thread or other connection
6. All locks and hold-down devices work properly
7. The pressure setting on the relief valve (if so equipped) is set correctly
8. Gaskets are in good repair
9. There is no obvious damage such as missing, broken or loose parts
10. There is no damage to the appliance that could impair safe operation (e.g. dents, cracks, corrosion, or other defects)
11. All swiveling elements rotate freely
12. Nozzle is securely attached
BEFORE BEING PLACED BACK IN SERVICE,
appliances must be inspected to this checklist:
1. All valves (if so equipped) open and close smoothly and fully
2. The waterway is clear of obstructions
3. There is no damage to any thread or other type connection
4. The pressure setting of the relief valve, if any, is set correctly
5. All locks and hold-down devices work properly
6. Internal gaskets are in accordance with NFPA 1962
7. There is no damage to the appliance that could impair safe operation (e.g. dents, cracks, corrosion, or other defects)
8. All swiveling connections rotate freely
9. There are no missing parts or components
10. There are no missing, broken, or worn lugs on couplings
NFPA 1962: Standard for the care, use, inspection, service testing, and replacement of fire hose, couplings, nozzles and fire hose appliances. Quincy, MA: National Fire
Protection Agency
WARNING
Equipment failing any part of the checklist is unsafe for use and must have the problem corrected
before use or being placed back into service. Operating equipment that has failed the checklist is a
misuse of this equipment.