©Copyright Task Force Tips LLC 2021
5
LIX-575 June 24, 2021 Rev00
3.0 GENERAL INFORMATION
The Extend-A-Gun VP is a remote controlled telescoping waterway with integrated shutoff valve designed to maximize firefighter safety
while expanding the capabilities of deck mounted Master Stream devices. Its function is to elevate a mounted Master Stream device
above other equipment on the apparatus, providing greater clearance and freedom of movement to the device. Operator controls for
both the telescoping waterway and integrated valve may be installed either at the pump panel or on the deck.
3.1 SPECIFICATIONS
Table 3.1
3.2 USE WITH SALT WATER
Use with salt water is permissible provided the equipment is thoroughly cleaned with fresh water after each use. The service life of the
equipment may be shortened due to the effects of corrosion, and is not covered under warranty.
MECHANICAL
Waterway Size
3” (76mm)
Safe Operating Range for Monitor Outlet:
Maximum flow rates at specified nozzle inlet pressures are
based on 950 lb (430 kg) maximum nozzle reaction force.
Read section 5.0 for installation requirements.
2010 gpm @ 80 psi
(7600 L/min @ 5.5 bar)
1800 gpm @ 100 psi
(6800 L/min @ 7 bar)
1600 gpm @ 120 psi
(6000 L/min @ 8.5 bar)
1250 gpm @ 200 psi
(4700 L/min @ 14 bar)
Maximum Pressure while flowing
250 psi (17 bar)
Maximum Hydrostatic Test Pressure with valve closed
600 psi (42 bar)
Travel
18” (457mm)
Valve gear ratio
36:1 (9 turns to close)
Lifting Capability
100 lbs (46 kg)
Lifting Time
5 sec
Lowering Time
10 sec
Air Supply Pressure
80 psi to 130 psi
Temperature Range
-25° to 135°F (-32° to 57°C)
*For temperatures below 32°F (0°C), valve must be drained after use to avoid damage.
ELECTRICAL
Nominal Operating Voltage
12 VDC
Voltage Range
9 to 15 VDC
Maximum Current Draw
2 amp @ 12 VDC