background image

Note 

1. Never touch the sensor. The sensitivity of the device will be reduced. Avoid dropping the unit. It 
is not shockproof. 
2. The forehead must be clean and dry, free of sweat and every kind of cosmetics such as creams, 
rouge, ... 
3.  Never open the device except for battery change 
4.  Wait  at  least  30  minutes  after  sporting  activities,  after  bathing  or  after  your  meal  to  do  a 
measurement. 
5.  If  a  body  temperature  which  is  lower  than  the  room  temperature  is  being  measured,  incorrect 
measurement values can be displayed. 
6.  To  ensure  optimal  performance  of  the  device,  please  read  the  "Technical  data"  section  for 
storage and operating conditions. 
7.  Please  pay  attention  to  the  recycling  instructions  for  the  batteries  and  for  your  device  when 
disposing of it. 
8. To  ensure the  correct function of the device,  we recommend  a measurement inspection  every 
two years. 
9. Some medications can cause an increase of the skin temperature which in turn may lead to an 
incorrect measurement. 
10. If you take a measurement while the skin is exposed to a heat source (e.g. solar radiation, air 
conditioning or heating), you will get an incorrect measurement of the values. 
11.  Avoid  extreme  temperature  fluctuations;  keep  your  thermometer  at  least  one  hour  at  room 
temperature before taking a measurement. 
12. To save battery time, remove your device from your smartphone after taking a measurement. 
 

Errors

 

Incorrect measurements can occur: 
1. When the sensor is directed to scars or to diseased skin. 
2. With trauma patients or patients who are subject to drug therapy. 
3. When the sensor is directed to skin that was exposed to a heat source. 

 

Device description  

 
 
 
 
 
 
 
 
 

The LED-Indicator 

red:  No contact or empty battery       

green:  Function OK 

 

The O/S-switch  

 

 

Switch position 1: Android, Switch position 2: Apple iOS 

 
Start-up / battery change 

Before  a  first  use,  just  pull  out  the  protective  strip  from  the  battery  compartment.  The  app  warns 
you  when  the    battery  is  empty.  The  device  can  not  take  measurements  any  longer.  Unplug  the 
device from your smartphone and proceed with the following steps: Open the battery compartment 
(avoid  any  use  of  sharp-edged  tools).  Carefully  remove  the  old  battery.  Insert  the  new  battery 
(minus-pole down) into the battery compartment. Close the battery compartment. 
 
 
 
 
 
 
 
 
 
 
 

 

 

Temperature measurement on the forehead 

1. Download the app OUcare (IRT OUcare) on your 
smartphone  or  open  the  already  downloaded  app. 
The  app  IRT  Oucare  starts  up  (button  is  still 
inactive). 

 
 
 

2. Bring the O/S switch to the position of 
the operating system of your smartphone 
(switch  position  1:  for  android,  2:  for 
Apple iOS). 

 

 
 
iOS is a trademark of Apple Inc., registered in the U.S. and other countries. Android is a trademark 
of Google Inc.

 

 

3. Plug the device into the  headphone jack of  your smartphone (button turns to  active). Turn the 
device into a suitable position for your measurement. 
 
 
4.  Remove  the  protective  cap  from  the  infrared  sensor  and 
direct  the  sensor  to  the  forehead.  Keep  a  distance  of  1  to  3 
cm  from  the  sensor  to  the  forehead!  The  measuring  time  is 
approximately  1  second.  During  the  measurement,  the 
distance  between  the  sensor  and  the  skin  should  not  be 
changed. 
 
5. Start the measurement with the button on the screen of your smartphone. 

 

6.  After  measuring,  disconnect  the  infrared  thermometer  from  your  smartphone.  Only  then  will    it 
turn off automatically. Otherwise the device will still consume power. 
 

Instructions on the infrared measurement 

Distance, Spot Size, and Field of View 
As the distance (D) from the object increases, the spot size (S) of the area measured by the unit 
becomes larger a ratio D:S = 1:1 (e.g. 10 cm distance = 10 cm spot size). To get the most accurate 
temperature reading, aim at the target as near as possible.  

 
Please take note of the following: 

Steam, dust, smoke, etc., can prevent accurate measurement by obstructing the unit’s optics.  
Not recommended for use in measuring shiny or polished metal surfaces (stainless steel, 
aluminum, etc.).   
The unit cannot measure through transparent surfaces such as glass or plastic. It will measure the 
surface temperature of the glass instead. 

 
Cleaning and disinfection 

Each pharmacy sells alcohol wipes (alcohol pads) from different vendors. With these, you can wipe 
the whole device. 

ATTENTION:

  Normal  thermometers  "feel"  the  temperature  of  the  object  to  be  measured  through 

contact  .  This  thermometer  works  infrared-based  and  "sees"  the  temperature.  The  "eye"  is  the 
infrared  sensor.  If  the  infrared  sensor  is  dirty,  the  thermometer  can  not  give  correct  readings. 
Please use  the protective cap after measurement to protect the infrared sensor! 
 

Protective cap 

Infrared sensor 

cap 

O/S Switch 

Battery cover 

Connector for              

headphone jack 

LED 

Reviews: