34
DHB MPE850 UTV Rev A | 409135 |
2
3
1
6 Test procedures at engine
6.2 Checking generator
6.2 Checking generator
G1 Generator
Stator
2
Rotor
3
GX1
3-pole connection at
stator generator (yellow
wires)
1
►
Check all electrical contacts for corrosion and proper mechanical connection.
►
Make a continuity test with all relevant wires:
Continuity test with multimeter:
d Continuity is required
(Resistance 0,3 ohm ±0,1 ohm at 20 °C)
– No continuity is permitted
GX1-
Engine
ground
A
B
C
GX1-
A
d
d
–
B
d
–
C
–
Engine ground
►
If the wires are defective, replace the stator.
►
Perform a visual inspection of the rotor.
►
If mechanical defects are present, for example at the internal magnets, replace the rotor.
Summary of Contents for Stampede 900 2017
Page 1: ...Technician s Repair and Service Manual 668061 B 2018...
Page 21: ...9 Repair and Service Manual Notes TABLE OF CONTENTS 668061...
Page 22: ...10 Repair and Service Manual TABLE OF CONTENTS Notes 668061...
Page 190: ......
Page 236: ......