EHP700L Battery-powered Pump

Greenlee / A Textron Company

4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070

2

Description

The Greenlee EHP700L Battery-powered Pump is a 

dual-stage pump that develops a maximum of 700 bar 

(10,000 psi). This pump is intended to provide hydraulic 

power for remote cutting, punching, and crimping tools.
This pump has a factory-set internal pressure relief 

valve.

Fill unit with hydraulic oil before 

 operating  pump.
Failure to fill unit with oil will result in 

damage to the pump.

Safety

Safety is essential in the use and maintenance of 

Greenlee tools and equipment. This instruction manual 

and any markings on the tool provide information for 

avoiding hazards and unsafe practices related to the 

use of this tool. Observe all of the safety information 

provided.

Purpose of this Manual

This manual is intended to familiarize all personnel with 

the safe operation and maintenance procedures for the 

Greenlee EHP700L Battery-powered Pump.
Keep this manual available to all personnel.
Replacement manuals are available upon request at no 

charge at www.greenlee.com.

Do not discard this product or throw away!

  

For recycling information, go to www.greenlee.com.

All specifications are nominal and may change as design 

improvements occur. Greenlee Textron Inc. shall not be liable for 

damages resulting from misapplication or misuse of its products.

KEEP THIS MANUAL

Table of Contents

Description .................................................................... 2
Safety ............................................................................ 2
Purpose of this Manual ................................................. 2
Important Safety Information .....................................3–5
Identification .................................................................. 6
Specifications ................................................................ 6
Features of the Pump .................................................... 7
Setup ............................................................................. 7
Operation ....................................................................8–9
Maintenance ................................................................ 10
Troubleshooting ........................................................... 11
Illustrations and Parts Lists ....................................12–18
 Main ....................................................................12–13
 Motor ....................................................................... 13
  Release Lever .......................................................... 14
  Pump Housing Unit .................................................. 15
  Pump Housing Cap Unit .......................................... 15
  Pump Housing Cap ................................................. 15
  Relief Valve .............................................................. 16
  Piston Pump ............................................................ 16
  Reservoir Assembly ................................................. 17
  Battery Plate ............................................................ 17
  Control Unit .............................................................. 18

Summary of Contents for Greenlee EHP700L

Page 1: ...nderstand all of the instructions and safety information in this manual before operating or servicing this tool Register this product at www greenlee com 52062054 REV 1 2012 Greenlee Textron Inc 8 12...

Page 2: ...l This manual is intended to familiarize all personnel with the safe operation and maintenance procedures for the Greenlee EHP700L Battery powered Pump Keep this manual available to all personnel Repl...

Page 3: ...t the pump to any system or system component other than those supplied by Greenlee Other manufacturers components may not with stand the maximum pressure and may fail Nearby personnel can be injured b...

Page 4: ...g this tool Failure to wear eye protection could result in serious eye injury from flying debris or hydraulic oil Inspect pump hoses couplers and fittings for wear or damage Replace worn damaged or mi...

Page 5: ...o not allow anything to contact the battery terminals Do not immerse the batteries in liquid Liquid may create a short circuit and damage the battery If batteries are immersed contact your service cen...

Page 6: ...0 76 l Maximum Operating Pressure 10 000 psi 700 bar Operating Temperature Range 10 F to 104 F 12 C to 40 C Dual Stage Pumping Action Rapid Advance 0 9 l min At Full Pressure 0 3 l min 1 3 8 Female C...

Page 7: ...coustical and optical warning signals in case of a detected fault The pump can be operated and transported in all positions without any oil leakages This tool is equipped with a circuit board incorpor...

Page 8: ...sult in severe injury or death Skin injection hazard Do not use hands to check for leaks Depressurize hydraulic system before servicing or disconnecting the hose High pressure oil easily punctures ski...

Page 9: ...r Crimping pressure has not been reached while motor was running Flashing light and audible alert for 1 second after cycle Error Required crimping pressure has not been reached Operator has interrupte...

Page 10: ...stments must be done by an authorized service center Daily Before use 1 Inspect the tool for wear or damage such as cracks gouges or chips 2 Inspect the tool for damage or leaks After use 1 Use a damp...

Page 11: ...act button simultaneously Run for approximately 10 seconds and then attempt to cut If unsuccessful return tool to a Greenlee Authorized Service Center Cold oil Start pump and hold retract button simul...

Page 12: ...109 2988 USA 815 397 7070 12 Illustration Main 32 23 11 7 4 24 25 26 27 28 29 30 31 2 3 22 21 20 18 9 15 16 14 16 13 16 17 All housing screws screwed in completely T 2 5 Nm max T 8 Nm max 12 32 19 1 1...

Page 13: ...25 Ring backup piston 1 26 52062193 Fitting 90 1 27 52060735 Cover 1 28 Screw 1 Key Part No Description Qty 29 52062228 Adapter 1 30 52062194 Coupler 3 8 female 1 31 52062241 Coupler cap 1 32 52062237...

Page 14: ...2 8 4 3 5 6 9 2 T 1 5 Nm max 5 T 1 5 Nm max 4 1 3 52062196 Release lever unit 1 Release lever 1 2 Screw 1 3 Compression spring 1 4 Bolt 1 5 Nut 1 Key Part No Description Qty 52049231 Motor gearbox un...

Page 15: ...6 Spring 1 7 Valve seat 1 8 O ring 1 52062238 Seal kit includes items marked with 52062239 Fastener kit includes items marked with 52062231 Pump housing cap 1 Cap 1 2 52062234 Sleeve 1 3 Seal ring 1 4...

Page 16: ...ew plug 1 3 Piston seal 1 4 Washer 1 5 Pump piston 1 6 Valve stem 1 7 Spring 1 52062238 Seal kit includes items marked with Key Part No Description Qty 1 2 3 6 7 8 10 9 5 4 52049232 Relief valve unit...

Page 17: ...t Reservoir Assembly 52062180 Reservoir assembly 1 52062217 Reservoir 1 2 Seal 2 3 Reservoir shaft 1 4 52055861 Clamp 10 pack 2 5 Bolt shoulder 2 6 O ring 1 7 Adapter 1 8 Reservoir plate 1 52062238 Se...

Page 18: ...1 Front panel 1 2 Control shaft 1 3 Screw 6 4 Board 1 5 Pin 1 6 Washer 2 7 Standoff 2 8 Knob 1 9 LCD display 1 Key Part No Description Qty 10 Switch 1 11 Retaining ring 1 12 Contact cover 1 13 Contact...

Page 19: ...EHP700L Battery powered Pump Greenlee A Textron Company 4455 Boeing Dr Rockford IL 61109 2988 USA 815 397 7070 19...

Page 20: ...8 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc is a subsidiary of Textron Inc USA Tel 800 435 0786 Fax 800 451 2632 Canada Tel 800 435 0786 Fax 800 524 2853 International Tel 1 815 397 70...

Reviews: