background image

Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

Page 4

FL-B101Q-HZ_manual (d0059)

The mode select headers are located on the Display Driver Board assembly. To change any of the modes, it is best to remove the 

Display Driver Board assembly from the case. Before removing the Display Driver Board assembly from the front of the case it is 

necessary to remove the rear cover and slide the main board back an inch, or remove it, to disengage the pin and socket connector 

between the main board and the display assembly.

Step 2

 

Remove the rear cover plate 

by pressing down lightly with a 

small flat bladed screw driver 

to release two plastic catches, 

on either side of the case and 

levering backwards.

Step 4

 

Starting with the top first, insert a 

small flat bladed screw driver and 

carefully lever the plastic catch up 

and tilt the Display Board assembly 

forward. Then repeat this action 

with the bottom catches.

Step 5

 

Remove the entire Display Board 

assembly by sliding it out of case.

Opening the Case to Access Mode Select Headers

INPU

T SIGNAL

 

CONDITI

ONER

MAIN BOARD

DISPLA

Y BOARD

DRI

VER BOARD

Meter Exploded view

Optional 16 Bit Isolated Analog Output Module

4 to 20 mA (0 to 20 mA)

Selection Position

0 to 10 V DC
Selection Position

Analog Output

Selection Header

CH1

CH2

Standard or 

Center Zero

Display Mode 

Select Header 

1

3

2

Operating Mode 

Select Header

1

3 4

2

Relay Activation Mode 

Select Header

b

a

c

d

Front view with bezel and 

 

scale faceplate removed.

Step 1 

Remove the front bezel by 

lightly levering the plastic 

catches up and forward in 

the a b c d sequence  shown. 

Then remove the cover and 

scale faceplate.

Step 3

 

Slide the Main Board back 

approximately 1” to disengage 

the pin and socket connection 

to the Display Driver   

Board.

Summary of Contents for FL-B101Q-HZ

Page 1: ...upply AC DC Auto sensing wide range supply PS1 std 85 265 VAC 50 400 Hz 95 300 VDC 4 2W PS2 15 48 VAC 50 400 Hz 10 72 VDC 4 2W Operating Temp 0 to 50 C Storage Temp 20 C to 70 C Relative Humidity 95 n...

Page 2: ...there are no menu or sub menus to navigate the programming and setup is quick and Span Buttons Span Zero Buttons Zero Set Point Button SP1 SP2 SP3 SP4 Front Panel Buttons Zero Button The Zero Button s...

Page 3: ...d Mode 3 Hysteresis Band between SP1 SP2 This mode enables the Hysteresis function In order for Hysteresis to function SP2 must be set to a value greater than SP1 and SP2 should be selected as High h...

Page 4: ...and carefully lever the plastic catch up and tilt the Display Board assembly forward Then repeat this action with the bottom catches Step 5 Remove the entire Display Board assembly by sliding it out o...

Page 5: ...SPAN but ton is pressed the input signal being applied must be more than 5 higher or lower than the previously memorized value of the input signal that was being applied when the other button was last...

Page 6: ...20mA If now the scaling has to be changed to read zero to full scale for an input of 0 to 20mA only the low 4 mA end needs to be recalibrated The high 20 mA end of the scaling is left untouched and so...

Page 7: ...d SP4 activate when input is lower than set point SP1 and SP3 activate when input is equal to or higher than set point SP2 activate when input is lower than set point SP1 SP3 and SP4 activate when inp...

Page 8: ...color overrides the SP1 color STEP A ENTER COLOR SET MODE Hold down ALL four setpoint buttons SP1 SP2 SP3 and SP4 and apply power to the meter The meter will light up in the Color Set Mode Release all...

Page 9: ...utton adjust the analog output as measured on the external multimeter to be the required value 20mA in this example When the HI button is pressed the UP or DOWN indicator LED shows the direction of ch...

Page 10: ...0 to 20 mA 4 to 20 mA or V 0 to 10 V output is header selectable Pin 19 Programming LOCK By connecting the LOCK pin to the COMMON pin the meter s programmed parameters can be viewed but not changed P...

Page 11: ...omponent Glossary SPAN Turn Clockwise to Increase Reading To the Right Rear SPAN Potentiometer Pot If provided the 15 turn SPAN pot is always on the right side as viewed from the rear of the meter Typ...

Page 12: ...I series IO board The adapter snaps on the 36x144 mm 1 42 x5 69 case and enables single unit or stack mounting in an existing 6 edgewise pointer meter cut out 100 0 25 50 75 100 0 25 50 75 SP1 SP2 SP3...

Page 13: ...6 Metal Surround Case includes screw mounting clips 25 OP MTLCLIP Screw Mounting Clips 2 pc to screw tighten slide brackets 8 OP N4 144X36 144x36mm clear lockable front cover NEMA 4X splash proof 30 O...

Reviews: