45
8-2. Series Output of PW18-1.3AT (three-channel power supply unit)
Fig.18 Complementary Connection Fig.19 Series Connection
Fig.20 Dual Pole (Same Pole) Connection
COM2
+
6V
Load
Load
Load
+
18V
-
18V
COM1
GND
COM2
Load
+
6V
COM1
0V to 36V
,
0A to 1.3A
Load
+
18V
-
18V
GND
COM2
Load
+
6V
The allowable current that may flow through the loads A
and B are restricted as shown below:
A
+
B
=
1.3
The GND terminal may be connected with COM2 or
+6V terminal.
COM1
Load
+
18V
-
18V
Load
A
B
GND