7-1-2. Specifying the number of units
Specify the number of units when configuring the unit to be the parallel master unit. If the number of units is incorrectly
specified, the unit cannot be operated in parallel master-slave operation.
Unit number: 1 unit is equal to a rated output power of 400W.
An 800W model is equal to 2 units, and a 1200W model is equal to 3 units.
When using a 400W model and an 800W model in parallel master-slave operation, the total number of
units must be 3.
Operation procedure
Follow the steps in
“7-1-1. Configuring the master
” to configure the unit as the
parallel master unit.
1. Press the ENTER/MEM key.
2. Turn the rotary encoder to specify the number of
units (including the master unit) for parallel
master-slave operation 2 to 6 units can be
selected.
3. Press the green-blinking ENTER/MEM key to
enter the setting.
After the setting is entered, the current indicator
stops blinking, remains lit for a short while, and
then starts blinking again.
4. Press the green-blinking ESC/KEY LOCK key.
The message shown in the figure on the left
appears.
If the same number of units has already been
specified for “P-
П
A", the following message is
displayed. The unit then restarts.
45