2-5-5. OVP
Description
If the OVP is tripped, the LSG Series will turn off
the load. The OVP levels can be set from 0V to
10% higher than the rating voltage.
Operation
1.
Press
Main
>
Configure[F5]
>
Protection[F1]
and set the
OVP Level
.
Range:
OVP Level: OFF, 0~Rating v 10%
Note: To turn OVP off, set the OVP voltage
greater than the current rating v 10%.
Display
2.596
V
500.06
mA
1.2982
w
CV B Value
15.000
CV A Value
15.000
LOAD
RS232
A Value
Fine
03/09/12
V
V
OVP Alarm
Please Press Enter
To Clear Alarm
OVP
OVP indicator
Alarm message
when OVP is
tripped
Mode
CV
I Range
L 0.7A
V Range
L 15V
Response
Fast
Configure
2-5-6. UnReg
Description
The UnReg error message will appear on the
display when the electronic load is operating in
an unregulated state.
Alarm
The UnReg indicator will appear on the display
when the set load is inadequate for the source.
To clear the UnReg indicator, increase the load
or reduce the load requirements.
Display
2.596
V
500.06
mA
1.2982
w
CV B Value
15.000
CV A Value
15.000
LOAD
RS232
A Value
Fine
31/Oct/2013
V
V
UnReg
UnReg indicator
Mode
CV
I Range
L 0.7A
V Range
L 15V
Response
Fast
Configure