20
1-4-6. Load Wire Connections
Description
The LSG-H Series has input terminals on both the front
and rear panels.
Follow the procedures below for all load connections.
Please adhere to the following precautions to ensure your
safety and to protect the unit from damage.
Connection
When connecting the LSG-H Series to the power source,
make sure that the polarity of the connection between the
DUT and the unit matches.
Ensure that the maximum input voltage is not exceeded.
The maximum input voltage is 800 volts.
Caution
If the polarity to the input terminals is reversed, the
reverse voltage protection function is tripped. The
reverse voltage protection function is tripped when
reverse voltages greater than about -0.3V are detected.
Warning
Do not touch any of the input terminals when the voltage
is applied to an input terminal.
Warning
Connecting the input terminals to the wrong polarity can
damage the
power source or the LSG-H Series.
Warning
The front panel and rear panel input terminals are
physically connected. Any voltage that is input to one set
of terminals will also appear on the other set of terminals.
DUT
-
+
Electronic
Load
+
-
Power
source
Power
source
Summary of Contents for LSG-1050H