92
3-2-2. Create a Program
Note
Before creating a program, it is necessary to set load
operation in internal memory (M001 - M256) to use for
each step, and to save it. See the save recall chapter for
further details, page 75 (
2-8. Save / Recall
).
Program Setting
Display Overview
Chain
Previous
Menu
LOAD
RS232
01/Oct/2017
Timing Edit for Program
On-Time:
Run:
Memory
0.1
Skip
M001
Short-Time:
P/F-Time:
Off-Time:
Off
Off
Off
STEP:
01
Program
Off
Recall
Default
Program
number
Step number in
selected program
Program
settings
PROG:
01
Program
settings
Operation
(1/2)
1.
Press
FUNC
.
Note:
Program
[F1] is off by default.
2.
Select
PROG
and select a program number to edit.
PROG: 01 ~ 16
3.
Select a
STEP
in the selected program.
STEP:
01 ~ 16
4.
Select
Memory
and select which memory location to
load for the selected step.
Settings loaded from the memory location will be
used for the selected step.
The same memory location can be used for multiple
steps.
Memory:
M001 ~ M256
5.
Set the Run setting for the step.
By default RUN is set to Skip.
The Auto setting will automatically start and go onto
the next step.
The Manual setting will wait for the user to press
Next
[F2] before running the step.
Run:
Skip, Auto, Manual
Summary of Contents for LSG-1050H
Page 24: ...14 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6...
Page 185: ...175 7 6 Operating Area 7 6 1 LSG 175H H Range M Range L Range...
Page 186: ...176 7 6 2 LSG 350H H Range M Range L Range...
Page 187: ...177 7 6 3 LSG 1050H H Range M Range L Range...
Page 188: ...178 7 6 4 LSG 2100H H Range M Range L Range...
Page 204: ......