56
4-1-2. Real time vs Equivalent time sampling mode
Background
The oscilloscope automatically switches between
two sampling modes, Real-time and Equivalent-
time, according to the number of active channels
and sampling rate.
Real-time
sampling
Once sampled data is used to reconstruct a single
waveform. Short-time events might get lost if the
sampling rate gets too high. This mode is used
when the sampling rate is relatively low (250MS/s
or lower).
Equivalent-time
sampling
Multiple numbers of sampled data are accumulated
to reconstruct a single waveform. ETS restores
more waveform detail but takes longer to update
the waveform. This mode is used when the
sampling rate becomes higher than 250MS/s. The
maximum equivalent-time sampling rate is
25GSa/s.
4-2.
Display
The Display section describes how to configure the display settings:
drawing type, waveform accumulation, contrast adjustment, and grid
settings.
4-2-1. Selecting vector or dot drawing
Procedure
9. Press the Display key.
Display
10. Press
Type
repeatedly to
select the waveform
drawing.
Type
Vectors
Types
Dots
Only the sampled dots are displayed.
Vectors
The sampled dots are connected by
lines.