5. Reliability Test Items
(Note3)
Item
Test Conditions
Remark
High Temperature Storage
Ta = 85
℃
240 hrs
Note 1,Note 4
Low Temperature Storage
Ta = -30
℃
240hrs
Note 1,Note 4
High Temperature Operation
Ts = 85
℃
240hrs
Note 2,Note 4
Low Temperature Operation
Ta =-30
℃
240hrs
Note 1,Note 4
Operate at High Temperature
and Humidity
+60
℃
, 90%RH max. 240 hrs
Note 4
Thermal Shock
-30
℃
/30 min ~ +85
℃
/30 min for a total 100
cycles, Start with cold temperature and end
with high temperature
Note 4
Vibration Test
Frequency range:10~55Hz
Stroke:1.5mm
Sweep:10Hz~55Hz~10Hz
2 hours for each direction of X. Y. Z.
(6 hours for total)
Mechanical Shock
100G 6ms,±X, ±Y, ±Z 3 times for each
direction
Package Vibration Test
Random Vibration :
0.015G*G/Hz from 5-200HZ, -6dB/Octave
from 200-500HZ
2 hours for each direction of X. Y. Z.
(6 hours for total)
Package Drop Test
Height:60 cm
1 corner, 3 edges, 6 surfaces
Electro Static Discharge
± 2KV, Human Body Mode, 100pF/1500Ω
Note 1: Ta is the ambient temperature of samples.
Note 2: Ts is the temperature of panel’s surface.
Note 3: In the standard condition, there shall be no practical problem that may affect the
display function. After the reliability test, the product only guarantees operation,
but doesn’t guarantee all the cosmetic specification.
Note 4: Before cosmetic and function test, the product must have enough recovery time,