Texecom Veritas Reflex Instruction Manual Download Page 1

 

Design:

 

Noise reduction circuits with maximum ground plane.

RF Immunity:

 

No false alarms from 80MHz to 1GHz at 50V/m,  

 

equivalent to a 700W uniform transmitter at 3m (10ft).

 

Complies with BS EN 61000-4-3 : 1997.

Electrostatic Discharge:

   No false alarm up to 8kV. 

Complies with BS EN 61000-4-2 : 1995.

Fast Transient Immunity:

  No false alarm up to ±1kV. 

Complies with BS EN 61000-4-4 : 1995.

High Energy Transient 
Immunity: 

 

No false alarm up to ±1kV.  

 

Complies with BS EN 61000-4-5 : 1995.

Conducted RF 

 

 

Susceptibility: 

No false alarms at 10Vrms.

 

Complies with BS EN 61000-4-6 : 1996.

Conducted Emissions:

  Complies with EN 55022 Class B.

Radiated Emissions:

 

Complies with EN 55022 Class B.

EMC:

 

Independently certified to EN 50130-4 : 1996.

Pulse Count: 

Adjustable Pulse Count. Internal link to select.

 

1. PHYSICAL

INS 156-7

-35°C (-31°F) to +60°C (+140°F)

90g (3oz) approx.

-20°C (-4°F) to +55°C (+131°F)

1.5m

(4'10")

2.5m

(8'4")

3.1m

(10'0")

2.0m

(6'7")

Regulatory information
Supplier

: Texecom Ltd, St. Crispin Way, Haslingden, Lancashire, BB4 

4PW, UK.

Weee Directive

: 2002/96/EC (WEEE directive): Products marked with 

this symbol cannot be disposed of as unsorted municipal waste 
in the European Union. For proper recycling, return this product 
to your local supplier upon the purchase of equivalent new 
equipment, or dispose of it at designated collection points. For 

more information see: www.recyclethis.info.

RoHs Directive:

 2002/95/EC RoHS Compliant. Hereby, Texecom 

declares that this device does not contain lead, mercury, cadmium, 
hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated 
depheny  ethers  (PBDE)  in  more  than  the  percentage  specified  by  EU 
directive 2002/95/EC, except exemptions stated in EU
directive 2002/95/EC annex.

CE Directive

: 2004/108/EC (CE directive): Hereby, Texecom declares that 

this device is in compliance with the essential requirements 
and other relevant provisions of Directive 2004/108/EC.

Maintenance:

 Test yearly by the installer

Warranty:

 5 year replacement warranty

Security grade:

 EN Grade 2   

Environmental class:

 Class II

Standards:

 EN50131-2-2, PD6662:2010

Disclaimer:

 The Veritas Reflex is not a complete alarm system, but only 

its part. Therefore Texecom does not accept any responsibility or liability 

for any damage that is claimed to be a result of an incorrect functioning 
of the Veritas Reflex detector. Texecom reserves the right to change the 

specification without a prior notice.

© 1994 - 2012 Texecom Ltd

2. ENVIRONMENTAL

3. FALSE ALARM PROTECTION

4. COVERAGE & PICK-UP

5. DETECTOR WIRING & SET UP

6. MOUNTING HEIGHT & SETTINGS

1.5M/4’10

2.0M/6’7

2.5M/8’4

3.1M/10’0

-0V

+12V

ALARM

TAMPER

Mounting

Height

JP1

JP2

Instruction Manual

Veritas Reflex

63mm

(2.5

)

40mm

(1.6

)

90mm

(3.6

)

2.5mm (0.1

) ABS

0.3 - 3.0m/s

LED OFF

JP2 - PULSE COUNT

1

2

3

1 - 10ft/s

DO NOT TOUCH

FAST

NORMAL

SLOW

LED ON

9-15V

DC

10mA @ 12V

DC

<24V

DC

50mA

(N/C)

<24V

DC

50mA

, 18

(N/C)

JP1 - LED

Reviews: