![Texecom Ricochet Impaq Contact-W Instruction Manual Download Page 1](http://html1.mh-extra.com/html/texecom/ricochet-impaq-contact-w/ricochet-impaq-contact-w_instruction-manual_1097358001.webp)
INS 468-7
ASSEMBLY
For rear tamper - fix both the detector AND the rear tamper insert
to the mounting surface. Activation of rear tamper will damage
product.
Rear Tamper Insert
Relear
n
MAG1 COM MAG2
Reed
Disable
Reed
Switch
Reed Disable
Magnet
Non-Ferrous Mounting Material
• Maximum Break = 30mm
• Minimum Make = 15mm
Ferrous Mounting Material
• Maximum Break = 15mm
• Minimum Make = 5mm
Note: Values depend on
mounting material. See Fig.1
Disabled
Enabled
Battery
Only replace with 3V Lithium CR123A.
Battery Safety
•
Do not throw into a fire
• Do not heat
• Do not charge
• Do not short circuit
• Do not disassemble
• Replace only with same or equivalent
type
• Always observe local regulations when
disposing of a battery
•
Detector will transmit low battery warning
when battery needs replacing
Relearn
Place jumper on Relearn
pin header and insert bat-
tery to learn device.
For wiring external
wired contacts/switches
LED
INTRODUCTION
• For wireless connectivity, detailed programming and system
set-up instructions please refer to the compatible RICOCHET™
technology enabled Premier Elite wireless expander
instructions.
• Featuring RICOCHET™ wireless technology the Impaq
Contact-W is designed for professional security installations.
• When using the Impaq Contact-W on an Entry/Exit route, or a
24HR door, or where chime is required, the device attributes
should be left at default “Always Awake”.
• Please see the Premier Elite 8XP-W/32XP-W Installation Manual
for details of how to change the device attributes.
Instruction Manual
Premier Elite Impaq Contact-W