Prestige Orbit QD/DT

Installation Manual

INS483

Summary of Contents for Prestige Orbit DT

Page 1: ...Prestige Orbit QD DT Installation Manual INS483...

Page 2: ...ing the sensor is impervious to and unaffected by weather conditions Additionally the combination of precision electronics digital white light filter and double shielding eliminates false alarms from...

Page 3: ...fts out of the location slot See fig 3 1 Mounting the Unit 4 3 Feed standard 8 core alarm cable into the cable entry bare the wires and connect to the removable terminal block as shown in fig 7 Screw...

Page 4: ...ut 1 Multiplexer PTZ Dome DVR etc 0V Supply 12VDC Supply 5 6 4 Always ensure when replacing the electronics module that the LED is facing forward so as to ensure correct alignment of the beam pattern...

Page 5: ...as trees shrubs ponds boiler flues and animals should be considered when positioning the detector The detector module is fitted with two sliding shutters to reduce the detection angle An additional se...

Page 6: ...ea being covered Use portions of the self adhesive silver mask supplied to the rear smooth side of the lens as shown in the diagrams below Always replace the lens the correct way up to ensure exact be...

Page 7: ...to be changed i e once for range twice for pulse count three times for LED 2 Wait four seconds until the blue LED indicator goes off 3 The indicator will then flash out the existing setting 4 To chan...

Page 8: ...be saved in the setup procedure when using the Walk Tester and it s use is highly recommended If you have difficulty in aligning the detector and you have issues with either short or long ranging a Wa...

Page 9: ...walk test mode by pressing the programme button once Fig 11 The Prestige Orbit s clear LED will then flash out its current settings Wait for the flashing sequence to finish The Prestige Orbit is now...

Page 10: ...z 10 525GHz 10 587GHz Albania Argentina Australia Austria Belgium Brazil Croatia Czech Republic Denmark France Germany Greece Holland Hungary Iceland Indonesia Italy Latvia Lithuania Malta Norway Port...

Page 11: ...e 5 seconds No 2 N CLOSED Volt free relay signal contact 24VAC DC 50mA with an integral 25R series resistor Alarm time 5 seconds Power Input 9 to 15 VDC Current 15mA 12V nominal Pulse Count 1 2 Temp C...

Page 12: ...state magnetically immune No 1 N OPEN Volt free relay signal contact 24VAC DC 50mA with an integral 25R series resistor Alarm time 5 seconds No 2 N CLOSED Volt free relay signal contact 24VAC DC 50mA...