background image

  8

 

ALTERING COVERAGE AT 2m  

   

MOUNTING HEIGHT

  6 

ANGLING THE DETECTOR

  4

  3

 

STANDARDS & APPROVALS

  2

 

ENVIRONMENTAL

  1 

PHYSICAL

8m

26

'

2

"

10m

32

'

9

"

15m

50

'

15m

50

'

2m

6

'

7

"

2m

6

'

7

"

2m

6

'

7

"

2m

6

'

7

"

-35°C (-31°F) to +60°C (+140°F)

150g (5oz) approx.

-35°C (-31°F) to +55°C (+131°F)

60mm

(2.4

40mm

(1.6

112.25mm

(4.4

2.5mm (0.1

) ABS

  QUALITY ASSURANCE

WARRANTY

10 year replacement warranty.

The 

Prestige TD

 is designed to detect the movement of an intruder and activate 

an alarm control panel. As the 

Prestige TD 

is not a complete alarm system, but only 

a part thereof, Texecom cannot accept responsibility or liability for any damages 
whatsoever based on a claim that the 

Prestige TD

 failed to function correctly.

Due to our policy of continuous improvement Texecom reserves the right to 

change specification without prior notice. All specifications are measured at 20ºC 
(68ºF). 

© 2003-2006 Texecom Ltd. Document Ref: PTD/EU/1.0-3 
The 

Prestige TD

 is protected by UK & International Registered Designs. Registered Design No’s: 3004997, 3004260 & 

3004261. Prestige is a Trademark of Texecom Ltd. 

C e r t i f i c a t e   N u m b e r :   F M   3 5 2 8 5

Professional Twin Dual PIR 

INSTALLATION INSTRUCTIONS

INS 

253-3

Quiescent Current 

=

10mA @ 12V

DC

Max Current* 

=

16mA @ 12V

DC

*Maximum current measured at detection/warm up 

!

!

0.3 - 3.0m/s

1 - 10ft/s

1

2

3

PULSE COUNT

www.texe.com

Ask your distributor today for the Texecom full colour Product Guide.

JP1

JP1

LED ON

LED OFF

DO NOT TOUCH

3.0m/9

10

2.5m/8

2

2.0m/6

7

1.5m/4

11

  7 

MOUNTING HEIGHT AND 

 

   

SETTINGS

4m

13

'

1

"

15m

50

'

2m

6

'

7

"

2m

6

'

7

"

!

  5

 

LATCH INPUT FUNCTIONS

 

  The latch terminal (see Section 4) can perform several different functions    
  depending on how it is connected: 

Latch connected to Set Positive (SW+, Set+):

 

The LEDs will be disabled while  

 

the system is set. Any detectors triggered while the system is set will indicate  

 

this by permanently lighting the alarm LED (upon unsetting the system).    

 

Detectors can be reset by taking the latch line high and then low again.

Latch connected to Alarm Positive (AL+, A+ve): 

The first detector activated  

 

while the system is set will indicate this with a slowly flashing alarm LED    

 

(upon unsetting the system). Detectors activated subsequently will indicate  

 

this by permanently lighting the alarm LED. Detectors can be reset by taking  

 

the latch line high and then low again.

ALARM

PIR Right

PIR Left

Made In England

EOL Resistor Selection

See Section 14

Detector Standard:

Independently certified to TS 50131-2-2 Grade 2 
Environmental Class II.

System Standard:

Suitable for use in a PD 6662/BS EN 50131-1 Grade 
2 system. Environmental Class II.

EMC:

Independently certified to EN 50130-4 : 1996.

RF Immunity:

 No false alarms from 80MHz to 2GHz at 10V/m. 
Complies with BS EN 61000-4-3 : 2002.

Electrostatic 

Discharge:

 No false alarms up to 8kV. 
Complies with BS EN 61000-4-2 : 1995.

Fast Transient 

Immunity:

 No false alarms up to ±4kV. 
Complies with BS EN 61000-4-4 : 1995.

High Energy 

Transient Immunity:

No false alarms up to ±2kV. Complies with BS EN 
61000-4-5 : 1995.

Conducted RF 

Susceptibility: 

No false alarms at 10Vrms. Complies with BS EN 
61000-4-6 : 1996.

Conducted & 

Radiated Emissions: 

Complies with EN 55022 Class B.

Product Identifier:

TD

Reviews: