System Outputs
Premier Elite Series Installation Manual
88
INS176-15
64 - Detector Fault
This output type activates when a detector fault occurs and
deactivates when the fault is reset.
65 - Detector Masked
This output type activates when a detector mask occurs and
deactivates when the mask is reset.
66 - Fault Present
This output type activates when a general fault occurs i.e. Line Fault,
AC Mains Fail, Detector Fault etc. and deactivates when the fault is
cleared.
67 - LED Control
This output type is always activate and deactivates when a User or
Engineers code is entered to gain access to a menu. The output
activates again 30 seconds after the user/engineer exits the menu.
This output type is for use with detectors that require 0V applied to
disable their LED’s.
68 - Full Arm Entry
This output type activates when the entry mode is started and
deactivates when the entry mode finishes whenever the system in
Full Armed.
69
–
Fire Sounder
This output type
activates when a Zone programmed as ‘Fire’, or a
Keypad Fire (4&6) causes a Fire Alarm in the selected area and
deactivates when the alarm is reset.
70
–
Confirmed PA
If an area is in PA alarm this output type activates when one of the
following happens.
another PA zone is activated
A tamper is detected from a different device
A second signal from a multi action PA
A global tamper within the timer period
71
–
Confirmed Alarm
If an area is in Alarm, this output type activates when a different zone
(not the entry route) is activated in the same area. This output type
deactivates at the end of the ‘confirmation time’ when a valid code is
entered within the Abort time, or when the alarm is reset.
72
–
Seismic Alarm*
*
Reserved for future use
Output Group - Zone
Any zone can be assigned to this output type. Select a zone number.then
select an output type from the following options:
Mimic
This output type activates when the selected zone is activated and
deactivates when the zone is secure. This output will work if the zone
is armed or disarmed.
MimicArm
This output type activates when the selected zone is activated and
deactivates when the zone is secured. This output will only work if the
zone is armed.
Alarm
This output type activates when the selected zone causes an alarm
and deactivates when the alarm is reset. This output will only work if
the zone is armed.
Tamper
This output type activates when the selected zone causes a Tamper
alarm and deactivates when the tamper is reset. This output will work
if the zone is armed or disarmed.
MimicLat
This output type activates when the selected zone is activated and
deactivates when the next time the zone is activated. This output will
work if the zone is armed or disarmed.
Omitted
This output type activates when the selected zone is omitted and
deactivates when the zone is reinstated.
Output Group - User Code Entered
Any user can be assigned to this output type.
This output type activates for 5 seconds when the selected User
code is entered.
Output Group - Control Timer
Select a Control Timer.
These output types activate when the respective control timer turns
on and deactivate when the timer turns off.
Output Group - PC Control
Select a PC Control.
These output types can be activated and deactivated using a PC
running the
Wintex UDL
software.
Output Group - Door Control
Select a Door Control from 1,1 to 1,4 (
48
), 1,1 to 1,8 (
88
), 1,1 to 2,8
(
168
) 1,1 to 8-8
(640)
.
These output types activate for the
duration of the ‘Door Strike’ timer
when a valid User code (assigned to the same door) is entered and
deactivates when the timer expires.
These output types are used in conjunction with the ‘Door Control’
User option (see page 127 for details).
Output Attributes
Assigning an attribute to an output will alter how the output works.
The following attributes can be assigned to any of the various types
listed.
Select attributes by pressing keys 1 to 8 (a letter on the display
means the attribute is selected, a ‘Dot’ on the display means the
attribute is not selected).
U - User Test
The output will activate when a user performs a User test (see page
133 for details).
I - Inverted
The output is inverted (an output that applies 0V when active will
become an output that applies 12V when active).
L - Latching
When activated, the output will remain on until a valid User code is
entered followed by reset.
1 - Use Pulse Period 1
When activated, the output will remain on for the duration of the
‘Pulse Period 1’ timer (see page
69 for details).
2 - Use Pulse Period 2
When activated, the output will remain on for the duration of the
‘Pulse Period 2’ timer (see page
69 for details).
3 - Use Pulse Period 3
When activated, the output will remain on for the duration of the
‘Pulse Period 3’ timer (see page
69 for details).
C - Only Active With Custom Output 1 Stage A
The output will only operate whilst ‘Custom Output Stage A’ is ‘On’
(see page ‘Custom Outputs’ for details).
R - Random
The output will activate randomly. A minimum and maximum ‘On’
time can also be programmed (see page 69 for details).