Front End Control Registers
140
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Front End
3.7.15 EADC Value Register (EADCVALUE)
Address 0x0008_0038 – Front End Control 2 EADC Value Register
Address 0x000B_0038 – Front End Control 1 EADC Value Register
Address 0x000E_0038 – Front End Control 0 EADC Value Register
Figure 3-23. EADC Value Register (EADCVALUE)
25
16
ABS_VALUE
R-0
15
14
13
9
8
EADC_SAT
_HIGH
EADC_SAT
_LOW
Reserved
ERROR_
VALUE
R-0
R-0
R-0
R-0
7
0
ERROR_VALUE
R-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 3-17. EADC Value Register (EADCVALUE) Register Field Descriptions
Bit
Field
Type
Reset
Description
25-16
ABS_VALUE
R
0
10-bit Absolute Value calculated by Front End Control Module with a resolution of
1.5625mV/bit
15
EADC_SAT_HIGH
R
0
EADC Saturation High Indicator
0 = EADC output is not saturated at high limit
1 = EADC output is saturated at high limit
14
EADC_SAT_LOW
R
0
EADC Saturation Low Indicator
0 = EADC output is not saturated at low limit
1 = EADC output is saturated at low limit
13-9
Reserved
R
00 000
8-0
ERROR_VALUE
R
0
Signed 9-bit Error value measured by Front End Control Module with a resolution of
1mV/bit