www.ti.com
5.1
CDCM7005 Software
Software Operation
Figure 3. TSW3003 Startup Screen
By using the provided CDCM7005 serial peripheral interface (SPI) software, the user can load settings to
the CDCM7005 internal registers. This must be performed every time the TSW3003 Demo Kit is powered
up, because the CDCM7005 has default settings that are loaded at power up and the settings may be
slightly different than the ones required to operate the Demo Kit. Executing the program brings up the
interface seen in
. The default settings are correct for a VCXO of 491.52 MHz and a 10 MHz
reference as on the TSW3003. The CDCM7005 GUI allows register settings to be saved and can be
loaded back in afterwards. This can be accomplished with the Save and Load Settings buttons near the
right side of the GUI.
It is recommended that any unused output clocks be tri-stated. In this case the TSW3003 only uses
OUT_MUX_1 to drive the DAC5687. OUT_MUX_0, OUT_MUX_2, OUT_MUX_3, OUT_MUX_4 should be
tri-stated unless there is a need to use the other output clocks.
6
TSW3003 Demonstration Kit
SLWU029D – October 2006 – Revised August 2007