44
SLWS245B – MAY 2014 – REVISED FEBRUARY 2017
Product Folder Links:
Copyright © 2014–2017, Texas Instruments Incorporated
CAL_CLK_SEL[3..0]: Set the frequency divider value used to derive the VCO calibration clock from the reference
frequency.
Table 6. CAL_CLK_SEL Scaling Factor Setting
CAL_CLK_SEL
Scaling Factor
CAL_CLK_SEL
Scaling Factor
1111
1/128
0111
NA
1110
1/64
0110
2
1101
1/32
0101
4
1100
1/16
0100
8
1011
1/8
0011
16
1010
1/4
0010
32
1001
1/2
0001
64
1000
1
0000
128
ICP[4..0]: Set the charge pump current.
Table 7. Charge Pump Current Set-Point
ICP[4..0]
Current (mA)
ICP[4..0]
Current (mA)
00 000
1.94
10 000
0.75
00 001
1.76
10 001
0.72
00 010
1.62
10 010
0.69
00 011
1.49
10 011
0.67
00 100
1.38
10 100
0.65
00 101
1.29
10 101
0.63
00 110
1.21
10 110
0.61
00 111
1.14
10 111
0.59
01 000
1.08
11 000
0.57
01 001
1.02
11 001
0.55
01 010
0.97
11 010
0.54
01 011
0.92
11 011
0.52
01 100
0.88
11 100
0.51
01 101
0.84
11 101
0.50
01 110
0.81
11 110
0.48
01 111
0.78
11 111
0.47