Table 4-1. Input/Output Connection
No.
Function
Description
J2
Buck1 Connector
Output of Buck1
J5
Buck2 Connector
Output of Buck2
J7
Buck3 Connector
Output of Buck3
J9
Buck4 Connector
Output of Buck4
J6
Buck1/2/3/4 VIN Connector
Apply power supply to this connector
J13
PMBus/I
2
C Interface connector
Communication via PMBus/I
2
C Interface
Table 4-2. Jumpers
No.
Functions
Description
JP1-PVIN34-Vin-PVIN12
Short VIN to PVIN34
Vin tied to PVIN34
JP3-PVIN12-PVIN34
Short PVIN12 with PVIN34
PVIN34 tied to PVIN12
JP10-3-4
Connect Cap to SS1
tied SS1 to C40
JP10-7-8
Connect Cap to SS2
tied SS2 to C42
JP10-11-12
Connect Cap to SS3
tied SS3 to C43
JP10-15-16
Connect Cap to SS4
tied SS4 to C44
4.2 Hardware Requirement
This EVM requires an external power supply capable of providing 4.5 V to 18 V at 6 A.
The EVM kit includes USB2ANY interface box which, when installed on a PC and connected to the EVM, permits
communication with the EVM via a GUI interface. The minimum PC requirements are:
• Microsoft
®
Windows
®
2000, Windows XP, or Windows 7 operating system
• USB port
• Minimum of 30MB of free hard disk space (100MB recommended)
• Minimum of 256MB of RAM
4.3 Hardware Setup
After connecting the power supply to J6 and turning on the power supply, the EVM regulates the output voltages
to the value listed in
. Additional input capacitance may be required in order to mitigate the inductive
voltage droop that may occur during a load transient event.
In order to change the output voltage by sending the digital control signal via a PC running the TPS65400
controller software and USB2ANY interface box, perform the following steps:
1. Connect the USB port of USB2ANY to the PC using the USB cable and the other end to J13 of the
TPS65400 using the supplied 30-pin ribbon cable (
). The connectors on the ribbon cable are
keyed to prevent incorrect installation.
2. Connect the power supply on J6 and turn on the power supply.
3. Run the software as explained in
.
Bench Test Setup Conditions
8
TPS65400 Buck Converter Evaluation Module User's Guide
SLVUAC4A – OCTOBER 2014 – REVISED MAY 2021
Copyright © 2021 Texas Instruments Incorporated