S_ON_OFF
I_SEL
J1
J2
R_SEL
RST
VCC
J4/J2
J1/J3
CR2032
Setup
2.3.4
EVM With LaunchPad
Load the code from this section into the MSP430F5529 of the LaunchPad. Refer to
for more details.
•
Put the S_ON_OFF selector in the OFF position.
•
Set the mode of operation through the MODE header (see
).
•
Remove jumpers VCC and RST of the LaunchPad.
•
Plug the EVM into the LaunchPad (MSP430F5529), according to the following table:
TPL5010EVM
MSP430 LaunchPad
J1/J3
J1.1
VDD_µC
J1/J3
pin 1
3V3
pin 4
GND
pin 4
GND
J4/J2
pin 2
GND
J4/J2
pin 2
GND
pin 4
WAKE
pin 4
P2.0
pin 10
RSTn
pin 10
RST
pin 18
DONE
pin 18
P2.3
VCC
3V3
RST
SBW RST
•
Insert a CR2032 coin cell battery in the battery holder (BT), alternatively, connect a voltage source
between the AUX_VDD and GND test points.
•
Configure the jumper J1 (RSTn connected to Q1, WAKE connected to Q2) and J2 (DONE connected
to IO), as explained in
NOTE:
Do not connect the coin cell battery and the voltage source to supply the evaluation board at
the same time.
Do not use the switch S2 (DONE), in this configuration, the DONE switch is connected to a
digital output pin of the microcontroller.
•
Put the S_ON_OFF selector in ON position, or turn on the external voltage source if it is used instead
of the coin cell battery.
Figure 9. Jumpers Configuration – EVM With LaunchPad
8
TPL5010 Evaluation Module
SNAU173 – January 2015
Copyright © 2015, Texas Instruments Incorporated