Texas Instruments TPD2E1B06DRLEVM User Manual Download Page 2

SETUP

www.ti.com

Table 2. IEC61000-4-2 Test Levels

Contact Discharge

Air Discharge

Class

Test Voltage [± kV]

Class

Test Voltage [± kV]

1

2

1

2

2

4

2

4

3

6

3

8

4

8

4

15

Table 3. Waveform Parameters in Contact Discharge Mode

Stress Level Step

Simulator Voltage

Ipeak ±15% [A]

Rise Time ±25%

Current at 30ns

Current at 60ns

[kV]

[nS]

±30% [A]

±30% [A]

1

2

7.5

0.8

4

2

2

4

15

0.8

8

4

3

6

22.5

0.8

12

6

4

8

30

0.8

16

8

Figure 1. Ideal Contact Discharge Waveform of the Output Current of the ESD Simulator at 4 kV

3

SETUP

This section describes the intended use of the EVM. A generalized outline of the procedure given in IEC-
61000-4-2 is described here. IEC-61000-4-2 should be referred to for a more specific testing outline. Basic
configurations for collecting S-parameters, Eye Diagrams, and ESD clamping waveforms are outlined as
well.

3.1

U1

A single TPD2E1B06DRL (U1) is configured with two USB2.0 Type A female connectors (J5 & J6) for
capturing Eye Diagrams. Using either J5 or J6 as input or output, attach to a USB2.0 compliant Eye
Diagram tester setup for the intended application, either transmitter or receiver.

2

TPD2E1B06DRLEVM

SLVU917 – August 2013

Submit Documentation Feedback

Copyright © 2013, Texas Instruments Incorporated

Summary of Contents for TPD2E1B06DRLEVM

Page 1: ...6DRL s IO protection pins A single TPD2E1B06DRL U2 is configured with 4 SMA J1 J4 connectors to allow 4 port analysis with a vector network analyzer Five TPD2E1B06DRL s U3 U7 are configured with test...

Page 2: ...ction describes the intended use of the EVM A generalized outline of the procedure given in IEC 61000 4 2 is described here IEC 61000 4 2 should be referred to for a more specific testing outline Basi...

Page 3: ...cedure ensures proper testing setup and method for both discharge tests Each IO has a Test Pad TP1 TP10 directly connected to it 3 3 1 Test Method and Set Up An example test setup is shown in Figure 2...

Page 4: ...ation of the measured signal is required Here are two possible procedures for testing U5 1 Using two 10X attenuators Attach two 10X attenuators to the oscilloscope channel being used Attach the 50 shi...

Page 5: ...VM board layout TPD2E1B06DRLEVM is a 4 layer board of FR 4 at 0 062 thickness Layers 2 and 3 are ground planes and not shown here Figure 3 TPD2E1B06DRLEVM Top Layer 5 SLVU917 August 2013 TPD2E1B06DRLE...

Page 6: ...BOARD LAYOUT www ti com Figure 4 TPD2E1B06DRLEVM Bottom Layer 6 TPD2E1B06DRLEVM SLVU917 August 2013 Submit Documentation Feedback Copyright 2013 Texas Instruments Incorporated...

Page 7: ...2E1B06DPL TI solution 4 J1 4 Connector SMA 0 25 X 0 375 inch 142 0701 231 Emerson Plug SMA Limited Detent SMP P PCB 2 J5 6 Connector 0 52 X 0 55 inch 87583 2010BLF FCI USB TYPE A Female 2 J7 8 Conn SM...

Page 8: ...ncy energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES 003 rules which are designed to provide reasonable protection against radio fr...

Page 9: ...na type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication This radio transmitter has been approved...

Page 10: ...roduct only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this product or 3 Use of this product only after you obtained the Technical Regulatio...

Page 11: ...erations per the user guidelines Exceeding the specified EVM ratings including but not limited to input and output voltage current power and environmental ranges may cause property damage personal inj...

Page 12: ...sponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related inf...