5
TPA3116D2, TPA3118D2, TPA3130D2
SLOS708G – APRIL 2012 – REVISED DECEMBER 2017
Product Folder Links:
Copyright © 2012–2017, Texas Instruments Incorporated
(1)
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2)
100 k
Ω
series resistor is needed if maximum slew rate is exceeded.
6 Specifications
6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)
(1)
MIN
MAX
UNIT
Supply voltage, V
CC
PV
CC
, AV
CC
–0.3
30
V
Input voltage, V
I
INPL, INNL, INPR, INNR
–0.3
6.3
V
PLIMIT, GAIN / SLV, SYNC
–0.3
GVDD+0.3
V
AM0, AM1, AM2, MUTE, SDZ, MODSEL
–0.3
PVCC+0.3
V
Slew rate, maximum
(2)
AM0, AM1, AM2, MUTE, SDZ, MODSEL
10
V/ms
Operating free-air temperature, T
A
–40
85
°C
Operating junction temperature , T
J
–40
150
°C
Storage temperature, T
stg
–40
125
°C
(1)
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. .
6.2 ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001
(1)
±2000
V
Charged-device model (CDM), per JEDEC specification JESD22-
C101
(2)
±500
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN
NOM
MAX
UNIT
V
CC
Supply voltage
PV
CC
, AV
CC
4.5
26
V
V
IH
High-level input
voltage
AM0, AM1, AM2, MUTE, SDZ, SYNC, MODSEL
2
V
V
IL
Low-level input
voltage
AM0, AM1, AM2, MUTE, SDZ, SYNC, MODSEL
0.8
V
V
OL
Low-level output
voltage
FAULTZ, R
PULL-UP
= 100 k
Ω
, PV
CC
= 26 V
0.8
V
I
IH
High-level input
current
AM0, AM1, AM2, MUTE, SDZ, MODSEL (V
I
= 2 V, V
CC
= 18 V)
50
µA
R
L
(BTL)
Minimum load
Impedance
Output filter: L = 10 µH, C = 680 nF
TPA3116D2, TPA3118D2
3.2
4
Ω
TPA3130D2
5.6
8
R
L
(PBTL)
Output filter: L = 10 µH, C = 1 µF
TPA3116D2, TPA3118D2
1.6
TPA3130D2
3.2
4
L
o
Output-filter
Inductance
Minimum output filter inductance under short-circuit condition
1
µH