Clocks
150
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Architecture
2.4.6.4.1 DCC1
As can be seen, the main oscillator (OSCIN) can be used for counter 0 as a “known-good” reference
clock. The clock for counter 1 can be selected from among 8 options. Refer to the DCC module chapter
for more details on the DCC usage.
Table 2-14. DCC1 Counter 0 Clock Inputs
Clock Source [3–0]
Clock / Signal Name
All other values
oscillator (OSCIN)
5h
HF LPO
Ah
test clock (TCK)
Table 2-15. DCC1 Counter 1 Clock / Signal Inputs
Key [3–0]
Clock Source [3–0]
Clock / Signal Name
Ah
0h
PLL1 free-running clock output
1h
PLL2 free-running clock output
2h
LF LPO
3h
HF LPO
4h
Flash pump oscillator
5h
EXTCLKIN1
6h
EXTCLKIN2
7
Reserved
8h-Fh
VCLK
All other values
any value
N2HET1[31]
2.4.6.4.2 DCC2
As can be seen, the main oscillator (OSCIN) can be used for counter 0 as a “known-good” reference
clock. The clock for counter 1 can be selected from among 2 options. Refer to the DCC module chapter
for more details on the DCC usage.
Table 2-16. DCC2 Counter 0 Clock Inputs
Clock Source [3–0]
Clock / Signal Name
others
oscillator (OSCIN)
0xA
test clock (TCK)
Table 2-17. DCC2 Counter 1 Clock / Signal Inputs
Key [3–0]
Clock Source [3–0]
Clock / Signal Name
Ah
0h
Reserved
1h
PLL2 post_ODCLK/8
2h
PLL2 post_ODCLK/16
3h-7h
Reserved
8h-Fh
VCLK
All other values
any value
N2HET2[0]