130
TMS320C6670 Peripheral Information and Electrical Specifications
Copyright 2012 Texas Instruments Incorporated
SPRS689D—March 2012
Multicore Fixed and Floating-Point System-on-Chip
TMS320C6670
•
SYSCLK7:
1/6-rate clock for slow peripherals and sources the SYSCLKOUT output pin.
•
SYSCLK8:
1/z-rate clock. This clock is used as slow_sysclck in the system. Default for this is 1/64. This is
programmable from /24 to /80.
•
SYSCLK9:
1/12-rate clock for SmartReflex.
•
SYSCLK10:
1/3-rate clock for SRIO only.
•
SYSCLK11:
1/6-rate clock for PSC only.
Only SYSCLK2, SYSCLK5, and SYSCLK8 are programmable on the TMS320C6670 device.
Note—
In case any of the other programmable SYSCLKs are set slower than 1/64 rate, then SYSCLK8
(SLOW_SYSCLK) needs to be programmed to either match, or be slower than, the slowest SYSCLK in the
system.
7.5.1.2 Main PLL Controller Operating Modes
The Main PLL Controller has two modes of operation: bypass mode and PLL mode. The mode of operation is
determined by the BYPASS bit of the PLL Secondary Control Register (SECCTL). In PLL mode, SYSCLK1 is
generated from the PLL output using the values set in the PLLM and PLLD fields in the MAINPLLCTL0 Register.
In bypass mode, PLL input is fed directly out as SYSCLK1.
All hosts must hold off accesses to the DSP while the frequency of its internal clocks is changing. A mechanism must
be in place such that the DSP notifies the host when the PLL configuration has completed.
7.5.1.3 Main PLL Stabilization, Lock, and Reset Times
The PLL stabilization time is the amount of time that must be allotted for the internal PLL regulators to become
stable after device powerup. The PLL should not be operated until this stabilization time has elapsed.
The PLL reset time is the amount of wait time needed when resetting the PLL (writing PLLRST = 1), in order for the
PLL to properly reset, before bringing the PLL out of reset (writing PLLRST = 0). For the Main PLL reset time value,
see
.
The PLL lock time is the amount of time needed from when the PLL is taken out of reset (PLLRST = 1) to when to
when the PLL Controller can be switched to PLL mode. The Main PLL lock time is given in
.
Table 7-13
Main PLL Stabilization, Lock, and Reset Times
Min
Typ
Max
Unit
PLL stabilization time
100
μs
PLL lock time
500 ×(PLLD
(1)
+1) × C
(2)
1 PLLD is the value in PLLD bit fields of MAINPLLCTL0 register
2 C = SYSCLK1(N|P) cycle time in ns.
PLL reset time
1000
ns
End of Table 7-13