TMP461EVM Software Overview
3.2.5 Data Capture Tab
The Data Capture Tab is where the temperature readings and set temperature thresholds are graphed.
Figure 3-15. TMP461EVM Data Capture Tab
In the bottom left of the Data Capture tab, there is a list of some device configurations that are also found
on the Basic Settings tab with the addition of the "SEND ONE SHOT" button. This button will enable only
when the conversion mode is set to "Shutdown." When this button is clicked, a One Shot command is sent
to the device and a single temperature conversion is done.
At the bottom right of the Data Capture tab, there are the GUI settings. These settings do not configure
the TMP461EVM, but can change how the GUI will handle the data collected from the TMP461EVM.
Temperature Scale:
this radio button group sets the units the temperature information is displayed
Show Threshold Sliders:
setting this checkbox will show the threshold sliders to the right of the graph as
well as displays for the temperature readings