TMP1075EVM Setup and Operation
21
SNOU157A – March 2018 – Revised April 2018
Copyright © 2018, Texas Instruments Incorporated
TMP1075EVM User's Guide
7.6
EVM Set-Up Tab
It is necessary to configure the TMP1075 slave address as 0x48 for communication with the EVM-GUI.
This is the default slave address.
Figure 24. TMP1075 Set-Up
Firmware
is allowed to check the firmware revision on the MSP430F5528 microcontroller by clicking the
Read
button or
Update The Firmware Revision
.
I2C Configuration
is to change the bus frequency and slave address.
Software Reset
performs software reset on the TMP1075 device by issuing a general call. After software
reset, the values displayed in the EVM software may be out of sync with the device register contents. To
sync register contents after software reset, click Read All in the Registers tab page.
Demo Mode
allows to operate the GUI without a hardware connected. In this mode, the handle is closed.
Clicking on any buttons or drop-down menu will be automatically closed the software GUI.
User Interface
polling rate refers to the time interval at which the GUI software queries the TMP1075
device. It can be configured here, but it will be changed automatically when changes are made to
resolution bit.