Default Jumper Positions
6
Default Jumper Positions
Table 3. TLV320AIC3256EVM-U Rev. A Default Jumper Positions
Jumper
Default Position
Description
W1
1-2
Selects between SCL and /SS lines
W2
1-2
Selects between SDA and MOSI lines
W3
1-2
Sets SPI_SELECT pin level to ground or IOVDD level
W4
Inserted
Reserved.
W5
Inserted
Connects MICDET to J5.4
W6
Removed
Reserved
W7
Inserted
Provides a means to measure AVDD Current
W8
2-3
Provides a means to measure DRVDD_HP Current and selects between 3.3V/1.8V
W9
1-2
Selects between 3.3V/1.8V for IOVDD Current
W10
Inserted
Provides a means to measure IOVDD Current
W11
Inserted
Provides a means to measure DVDD Current
W12
Inserted
Provides a means to measure DVDD_CP Current
18
TLV320AIC3256EVM-U Evaluation Module
SLOU294B – July 2010 – Revised October 2012
Copyright © 2010–2012, Texas Instruments Incorporated