background image

IMPORTANT NOTICE

Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.

TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.

TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.

TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.

Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.

Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.

Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.

In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.

No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.

Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.

TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which
have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such
components to meet such requirements.

Products

Applications

Audio

www.ti.com/audio

Automotive and Transportation

www.ti.com/automotive

Amplifiers

amplifier.ti.com

Communications and Telecom

www.ti.com/communications

Data Converters

dataconverter.ti.com

Computers and Peripherals

www.ti.com/computers

DLP® Products

www.dlp.com

Consumer Electronics

www.ti.com/consumer-apps

DSP

dsp.ti.com

Energy and Lighting

www.ti.com/energy

Clocks and Timers

www.ti.com/clocks

Industrial

www.ti.com/industrial

Interface

interface.ti.com

Medical

www.ti.com/medical

Logic

logic.ti.com

Security

www.ti.com/security

Power Mgmt

power.ti.com

Space, Avionics and Defense

www.ti.com/space-avionics-defense

Microcontrollers

microcontroller.ti.com

Video and Imaging

www.ti.com/video

RFID

www.ti-rfid.com

OMAP Applications Processors

www.ti.com/omap

TI E2E Community

e2e.ti.com

Wireless Connectivity

www.ti.com/wirelessconnectivity

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2012, Texas Instruments Incorporated

Summary of Contents for SN65HVD257

Page 1: ...d Filtering Configuration 10 3 4 Using Customer Installable IO Options for Current Limiting Pull up or down Noise Filtering 11 3 5 Using customer installable IO options for 3 3V IO 11 4 SN65HVD257 EVM...

Page 2: ...odes normal mode and silent mode selected on pin 8 The FAULT pin indicates TXD dominant time out RXD dominant time out thermal shut down and under voltage faults Figure 1 SN65HVD257 Basic Block Diagra...

Page 3: ...combine the RXD outputs of both branches During dominant bits low were the branches do not match the XOR the circuit outputs a logic high A small RC filter on the output eliminates false outputs due t...

Page 4: ...such as GND VCC TXD RXD CANH CANL S FAULT The EVM supports many options for CAN bus configuration It is pre configured with two 120 resistors that may be connected on the bus via jumpers a single resi...

Page 5: ...5 GND 1 TP8 RXD 1 TP1 GND 1 C17 DNI U1 SN65HVD257 TXD 1 GND 2 Vcc 3 RXD 4 FLT 5 CANL 6 CANH 7 S 8 C13 1uF R10 DNI R17 0 U5 SN65HVD257 TXD 1 GND 2 Vcc 3 RXD 4 FLT 5 CANL 6 CANH 7 S 8 R19 330 C1 DNI TP7...

Page 6: ...60 load for CAN transceiver parametric measurement JMP10 4 pin header Connection for access to transceiver 2 CAN bus output CANH2 CANL2 GND GND Connect 120 CAN termination to the bus Used in combinat...

Page 7: ...XDprime RXD Receive Data 7 GND GND 8 VCC Pin 3 of Transceiver VCC 9 S2 Pin 5 of Transceiver 2 Used for Mode control 10 FLT2 Pin 8 of Transceiver 2 Indicates fault with transceiver 2 11 GND GND 12 FLT3...

Page 8: ...MP1 and TP10 This output indicates a RXD DTO TXD DTO Thermal Shut Down or undervoltage fault with transceiver 1 3 1 7 FLT 2 FAULT pin 5 transceiver 2 JMP1 TP23 Pin 5 of transceiver 2 is the fault outp...

Page 9: ...y the split capacitance is in the range of 4 7nF to 100nF Keep in mind that this is the common mode filter frequency not a differential filter that will impact the differential CAN signal directly Tab...

Page 10: ...us filter environment Filter caps may be used in combination with L1 CM choke To add extra protection for system level transients and ESD protection use the D1 and D2 Transient Protection Transient ES...

Page 11: ...ode pin input from JMP1 or PU or S U1 Input R1 JMP2 R2 NA C1 JMP2 PD to S U1 R27 S Mode pin input from JMP1 or PU or S U2 Input R25 JMP2 R26 NA C21 JMP2 PD to S U2 FAULT3 is the combined RXD output fr...

Page 12: ...r 1 JMP3 may be used to route these signals to an external host processor or test system Make sure that the MODE JMP2 jumper settings are not conflicting with signals to JMP3 JMP2 transceiver 1 config...

Page 13: ...nsceiver 2 Ensure JMP7 and JMP8 are not configured to conflict if TP19 is used as the input connection 4 2 4 FLT2 Output JMP7 TP23 Pin 5 of transceiver 2 is the fault output of the transceiver This ou...

Page 14: ...2 JMP5 JMP10 Header 1x4 HDR_THVT_1X4_100 ANY ACT45B or B82789 series 17 2 L1 L2 DNI TDK EPCOS CM choke 18 4 R1 R16 R25 R40 4 7k 805 ANY R2 R3 R8 R15 R17 R20 R21 R26 19 11 0 805 ANY R27 R32 R39 20 4 R3...

Page 15: ...o handling the product This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI a...

Page 16: ...egulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided...

Page 17: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments SN65HVD257EVM...

Reviews: