![Texas Instruments RM48 series Technical Reference Manual Download Page 222](http://html1.mh-extra.com/html/texas-instruments/rm48-series/rm48-series_technical-reference-manual_1095569222.webp)
PMM Registers
222
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
Power Management Module (PMM)
3.4.16 LogicPD PSCON Diagnostic Compare Status Register 1 (LPDDCSTAT1)
Figure 3-18. LogicPD PSCON Diagnostic Compare Status Register 1 (LPDDCSTAT1)
[offset = B0h]
31
24
Reserved
R-0
23
20
19
18
17
16
Reserved
LCMPE[3]
LCMPE[2]
LCMPE[1]
LCMPE[0]
R-0
R/W1CP-0
R/W1CP-0
R/W1CP-0
R/W1CP-0
15
8
Reserved
R-0
7
4
3
2
1
0
Reserved
LSTC[3]
LSTC[2]
LSTC[1]
LSTC[0]
R-0
R-0
R-0
R-0
R-0
LEGEND: R/W = Read/Write; R = Read only; W1CP = Write 1 to clear in privilege mode only; -
n
= value after reset
Table 3-17. LogicPD PSCON Diagnostic Compare Status Register 1 (LPDDCSTAT1)
Field Descriptions
Bit
Field
Value
Description
31-20
Reserved
0
Read returns 0. Writes have no effect.
19-16
LCMPE[3-0]
Logic Power Domain Compare Error
Each of these bits corresponds to a logic power domain:
Bit 3 for PD5,
Bit 2 for PD4,
Bit 1 for PD3,
Bit 0 for PD2.
Read in User and Privileged Mode. Write in Privileged mode only.
0
Read: PSCON signals are identical.
Write: Writing 0 has no effect.
1
Read: PSCON signal compare mismatch identified.
Write: Clears the corresponding LCMPE bit, if set.
15-4
Reserved
0
Read returns 0. Writes have no effect.
3-0
LSTC[3-0]
Logic Power Domain Self-test Complete
Each of these bits corresponds to a logic power domain:
Bit 3 for PD5,
Bit 2 for PD4,
Bit 1 for PD3,
Bit 0 for PD2.
Read in User and Privileged Mode. Writes have no effect.
0
Self-test is ongoing if self-test mode is entered.
1
Self-test is complete.