ADC10_B Registers
16.3.6 ADC10MCTL0 Register
ADC10_B Conversion Memory Control Register
Figure 16-17. ADC10MCTL0 Register
7
6
5
4
3
2
1
0
Reserved
ADC10SREFx
ADC10INCHx
r0
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by software and changing these fields
immediately shows effect also when a conversion is active.
Table 16-8. ADC10MCTL0 Register Description
Bit
Field
Type
Reset
Description
7
Reserved
R
0h
Reserved. Always reads as 0.
6-4
ADC10SREFx
RW
0h
Select reference. It is not recommended to change this setting while a
conversion is ongoing.
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
000b = V(R+) = AVCC and V(R-) = AVSS
001b = V(R+) = VREF and V(R-) = AVSS
010b = V(R+) = VEREF+ buffered and V(R-) = AVSS
011b =V(R+) = VEREF+ and V(R-) = AVSS
100b = V(R+) = AVCC and V(R-) = VEREF-
101b = V(R+) = VREF and V(R-) = VEREF-
110b = V(R+) = VEREF+ buffered and V(R-) = VEREF-
111b = V(R+) = VEREF+ and V(R-) = VEREF-
3-0
ADC10INCHx
RW
0h
Input channel select. Writing these bits select the channel for a single-conversion
or the highest channel for a sequence of conversions. Reading these bits in
ADC10CONSEQ = 01,11 returns the channel currently converted.
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
0000b = A0
0001b = A1
0010b = A2
0011b = A3
0100b = A4
0101b = A5
0110b = A6
0111b = A7
1000b = VEREF
1001b = VREF-/VEREF-
1010b = Temperature diode from REF module
1011b = (AVCC – AVSS) / 2
1100b = A12
1101b = A13
1110b = A14
1111b = A15
456
ADC10_B Module
SLAU272C – May 2011 – Revised November 2013
Copyright © 2011–2013, Texas Instruments Incorporated