RTC_B Registers
13.3.23 RTCADAY Register – Hexadecimal Format
Real-Time Clock Day of Month Alarm Register – Hexadecimal Format
Figure 13-24. RTCADAY Register
7
6
5
4
3
2
1
0
AE
0
0
Day of month
rw
r-0
r-0
rw
rw
rw
rw
rw
Table 13-24. RTCADAY Register Description
Bit
Field
Type
Reset
Description
7
AE
RW
undefined
Alarm enable
0b = This alarm register is enabled
1b = This alarm register is disabled
6-5
0
R
0h
Always reads as 0.
4-0
Day of month
RW
undefined
Day of month. Valid values are 1 to 31.
13.3.24 RTCADAY Register – BCD Format
Real-Time Clock Day of Month Alarm Register – BCD Format
Figure 13-25. RTCADAY Register
7
6
5
4
3
2
1
0
AE
0
Day of month – high digit
Day of month – low digit
rw
r-0
rw
rw
rw
rw
rw
rw
Table 13-25. RTCADAY Register Description
Bit
Field
Type
Reset
Description
7
AE
RW
undefined
Alarm enable
0b = This alarm register is enabled
1b = This alarm register is disabled
6
0
R
0h
Always reads as 0.
5-4
Day of month – high
RW
undefined
Day of month – high digit. Valid values are 0 to 3.
digit
3-0
Day of month – low
RW
undefined
Day of month – low digit. Valid values are 0 to 9.
digit
403
SLAU272C – May 2011 – Revised November 2013
Real-Time Clock B (RTC_B)
Copyright © 2011–2013, Texas Instruments Incorporated