RTC_B Registers
13.3.18 RTCAMIN Register – Hexadecimal Format
Real-Time Clock Minutes Alarm Register – Hexadecimal Format
Figure 13-19. RTCAMIN Register
7
6
5
4
3
2
1
0
AE
0
Minutes
rw
r-0
rw
rw
rw
rw
rw
rw
Table 13-19. RTCAMIN Register Description
Bit
Field
Type
Reset
Description
7
AE
RW
undefined
Alarm enable
0b = This alarm register is enabled
1b = This alarm register is disabled
6
0
R
0h
Always reads as 0.
5-0
Minutes
RW
undefined
Minutes. Valid values are 0 to 59.
13.3.19 RTCAMIN Register – BCD Format
Real-Time Clock Minutes Alarm Register – BCD Format
Figure 13-20. RTCAMIN Register
7
6
5
4
3
2
1
0
AE
Minutes – high digit
Minutes – low digit
rw
rw
rw
rw
rw
rw
rw
rw
Table 13-20. RTCAMIN Register Description
Bit
Field
Type
Reset
Description
7
AE
RW
undefined
Alarm enable
0b = This alarm register is enabled
1b = This alarm register is disabled
6-4
Minutes – high digit
RW
undefined
Minutes – high digit. Valid values are 0 to 5.
3-0
Minutes – low digit
RW
undefined
Minutes – low digit. Valid values are 0 to 9.
400
Real-Time Clock B (RTC_B)
SLAU272C – May 2011 – Revised November 2013